Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FAMILY ONE EXTERIORS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FAMILY ONE EXTERIORS LLC in 4445/47 CENTRAL AVE, OCEAN CITY, NJ 08226 (NAICS 238170). OSHA activity number 344180211.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Family ONE Exteriors LLC — free Get an email when a new federal OSHA severe-injury report for Family ONE Exteriors LLC is published. One employer, no account, unsubscribe in one click.
Site address
4445/47 CENTRAL AVE
City
OCEAN CITY
State
NJ
ZIP
08226
Mailing
17 LYNN DRIVE, OCEAN, NJ 07712
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 14, 2020
Abate by
Feb 28, 2020
Penalty
Initial $3,978 · Current $2,350 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:    a)    West side of house, 4445-47 Central Ave, Ocean City: Employee used the closed Werner Type 1, 6 foot fiberglass step ladder, to access the pump jack scaffold platform from the approximate 2 foot wide 3rd floor over hang; bottom of ladder was resting where the top of overhang met the front wall and leaning on the platform, on or about 07/23/2019.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $2350
  • — Z (S) $3978

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 14, 2020
Abate by
Feb 28, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    a)    West side of house, northeast corner of 45th Street and Central Avenue:  An employee without proper fall protection, was working from the approximate 27 foot level on an improperly setup pump jack scaffold platform, on or about 07/23/2019.     NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 J02

Serious Gravity 10 6 instances 4 exposed
Issued
Jan 14, 2020
Abate by
Feb 28, 2020
Penalty
Initial $3,978 · Current $2,350 Reduced
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary:    a)    West side of house, 4445-47 Central Avenue: The poles for the pump jack scaffold setup and used by an employee without proper fall protection working from the approximate 27 foot level was only secured with a brace for each aluminum pole on the roof at approximately 38 feet, on or about 07/23/2019;    b)    North side of house, 4445-47 Central Avenue: The four poles for the pump jack scaffold setup and used by employees to install cedar siding was only secured with a brace for each aluminum pole on the roof at approximately 35 feet, on or about 07/23/2019.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $2350
  • — Z (S) $3978

View Family ONE Exteriors LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344180211.