On , OSHA opened a planned safety inspection of MIKE WELLS DBA WNY SPARTAN HOME IMPROVEMENTS in 90 PETER STREET, BUFFALO, NY 14207 (NAICS 238160). OSHA activity number 344208384.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MIKE WELLS DBA WNY SPARTAN HOME IMPROVEMENTS
- Site address
- 90 PETER STREET
- City
- BUFFALO
- State
- NY
- ZIP
- 14207
- Mailing
- 410 KOHL STREET, NORTH TONAWANDA, NY 14120
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 G01 I
- Issued
- Aug 26, 2019
- Penalty
- Initial $2,842 · Current $1,800 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 08/02/19, at a jobsite on a 2-story house at 90 Peter Street, Buffalo, NY: Two Ladder Jack Scaffolds were erected on the north side of the house. Two employees were working from the aluminum pik of the scaffold that was nearest to the back of the house. The employees were exposed to a fall of approx. 18 ft. because no fall protection system was being utilized. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1800
- — Z (S) $2842
1926.452 K05
- Issued
- Aug 26, 2019
- Penalty
- Initial $2,842 · Current $1,700 Reduced
General-duty citation text
29 CFR 1926.452(k)(5): Scaffold platforms were bridged on to another. a) On or about 08/02/19, at a jobsite on a 2-story house at 90 Peter Street, Buffalo, NY: Two Ladder Jack Scaffolds were erected on the north side of the house. There was an approx. 6 ft. gap between the aluminum pik on the front ladder jack scaffold and the aluminum pik on the back ladder jack scaffold. That gap was bridged by putting two wood planks side by side, spanning the gap. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1700
- — Z (S) $2842
1926.501 B11
- Issued
- Aug 26, 2019
- Penalty
- Initial $2,842 · Current $1,800 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 08/02/19, at a jobsite on a 2-story house at 90 Peter Street, Buffalo, NY: Two employees engaged in roofing tear-off work on the steep roof on the north side of the house were exposed to a fall of approx. 20 ft. because fall protection was not being utilized. Pitch of the roof was approx. 12 in 12. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1800
- — Z (S) $2842
1926.1053 B01
- Issued
- Aug 26, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 08/02/19, at a jobsite on a 2-story house at 90 Peter Street, Buffalo, NY: A Ladder Jack Scaffold was erected on the north side of the house. An extension ladder was used by employees to access the scaffold. The side rails of that ladder extended approx. 32 in. above the aluminum pik on the scaffold. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Mike Wells DBA WNY Spartan Home Improvements
View Mike Wells DBA WNY Spartan Home Improvements's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344208384.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.