SIDNEY, OH —
OSHA Inspection: SCHWANS MAMA ROSA'S LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SCHWANS MAMA ROSA'S LLC in 1910 FAIR RD, SIDNEY, OH 45365 (NAICS 311999). OSHA activity number 344214838.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCHWANS MAMA ROSA'S LLC
- Site address
- 1910 FAIR RD
- City
- SIDNEY
- State
- OH
- ZIP
- 45365
- Mailing
- 1910 FAIR RD, SIDNEY, OH 45365
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311999
- Employees
- 306
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 D
- Issued
- Sep 16, 2019
- Abate by
- Oct 9, 2019
- Penalty
- Initial $13,260 · Current $6,630 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): Schwan's MaMa Rosas LLC in Sidney, Ohio, in Production Room two: On or about August 2, 2019, an employee was exposed to amputation injury in that the Grote Peperoni Machine and blade guides were not locked out prior to the performance of cleaning activities. The employer did not ensure energy control applications steps to control the electrical energy source were implemented prior to employees accessing the pinch point to remove food debris from chain and sprocket. The employer did not: - Turn off or shut down the equipment. - Physically operate energy isolating devices to control energy sources and affix lockout device(s). - Ensure that all potentially hazardous stored or residual energy was relieved, disconnected, and rendered safe. - Verify that isolation and de-energization of the machine or equipment had been accomplished.
Recent events (2)
- — I (S) $6630
- — Z (S) $13260
1910.147 C07 I
- Issued
- Sep 16, 2019
- Abate by
- Oct 9, 2019
- Penalty
- Initial $13,260 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: Schwan's MaMa Rosas LLC in Sidney, Ohio, in Production Room Two: On or about August 2, 2019, the employer did not ensure employees were adequately trained on the Grote Pepperoni specific energy control procedures. Employees tasked with the performance of activities such as, but not limited to, cleaning of the Grote Peperoni Machine and blade guides were exposed to amputation and caught in hazard in that the equipment was not adequately de-energized.
Recent events (2)
- — I (S) $0
- — Z (S) $13260
More inspections at Schwans Mama Rosa'S LLC
View Schwans Mama Rosa'S LLC's full OSHA safety record →
More inspections in this industry (NAICS 311999)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344214838.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.