Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: M V SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of M V SERVICES, INC. in W7327 ANDERSON AVENUE, SHAWANO, WI 54166 (NAICS 238140). OSHA activity number 344219415.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M V Services, INC. — free Get an email when a new federal OSHA severe-injury report for M V Services, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
M V SERVICES, INC.
Site address
W7327 ANDERSON AVENUE
City
SHAWANO
State
WI
ZIP
54166
Mailing
1402 4TH STREET, MARATHON, WI 54448
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
9
Ownership type
A

2 citations on file for this inspection.

1926.451 C01 II

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 31, 2019
Penalty
Initial $2,842 · Current $1,989 Reduced
29 CFR 1926.451(c)(1)(ii): Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).  a)  On or about August 8, 2019 at W7327 Anderson Avenue in Shawano - east exterior wall of building, tubular welded frame scaffold four levels high was not adequately tied/braced; one wire tie used to secure one end of the scaffold.  Employee working from all levels up to a height greater than twenty feet.  b)  On or about August 8, 2019 at W7327 Anderson Avenue in Shawano - south exterior wall of building, tubular welded frame scaffold four levels high was not adequately tied/braced; two wire ties were used to secure one end of the scaffold.  Employee working from all levels up to a height greater than twenty feet.
Recent events (2)
  • — I (S) $1989.4
  • — Z (S) $2842

1926.451 G01 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 31, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  On August 8, 2019 at W7327 Anderson Avenue in Shawano, an employee removed the guardrails in a scaffold hoist area at twenty feet above surface level; a mortar tub was hoisted to the open edge.  The guardrails were not re-installed after the tub was removed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View M V Services, INC.'s full OSHA safety record →