Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PACK LOGIX, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PACK LOGIX, LLC in W222N744 CHEANEY RD., WAUKESHA, WI 53186 (NAICS 561910). OSHA activity number 344249156.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pack Logix, LLC — free Get an email when a new federal OSHA severe-injury report for Pack Logix, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PACK LOGIX, LLC
Site address
W222N744 CHEANEY RD.
City
WAUKESHA
State
WI
ZIP
53186
Mailing
W222 N744 CHEANEY RD., WAUKESHA, WI 53186
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561910
Employees
34
Ownership type
A

2 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 4, 2019
Penalty
Initial $9,282 · Current $4,651 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:    (a) On or about March 8, 2019, and at times prior, the employer failed to provide authorized employee training to employees that engaged in service and maintenance activities. As a result, the employer did not ensure that maintenance employees were knowledgeable and possessed the skills necessary to safely apply, use, and remove energy control devices when service and maintenance activities are performed.
Recent events (2)
  • — I (S) $4651
  • — Z (S) $9282

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in or was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  (a) On or about March 8, 2019, and at times prior, the employer did not ensure that employees implemented energy control procedures for the Orion packaging machine during the repair work being performed. All energy sources were not isolated prior to engaging in the maintenance or servicing activities.   As a result, the remaining applicable energy control elements: machine isolation [1910.147(d)(3)], lock-out/tag-out device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)], were not implemented to protect employees from caught-in or amputation injury during machine servicing and maintenance activities.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Pack Logix, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344249156.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.