Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ENERFAB POWER & INDUSTRIAL, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ENERFAB POWER & INDUSTRIAL, INC. in 1781 U.S. HIGHWAY 52, MOSCOW, OH 45153 (NAICS 811310). OSHA activity number 344279039.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Enerfab Power & Industrial, INC. — free Get an email when a new federal OSHA severe-injury report for Enerfab Power & Industrial, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1781 U.S. HIGHWAY 52
City
MOSCOW
State
OH
ZIP
45153
Mailing
4955 SPRING GROVE AVE, CINCINNATI, OH 45232
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
10
Ownership type
A

2 citations on file for this inspection.

1910.22 A03

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Oct 10, 2019
Abate by
Oct 23, 2019
Penalty
Initial $12,503 · Current $0 Reduced
29 CFR 1910.22(a)(3): Surface conditions. The employer must ensure: Walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.  On April 19, 2019, on the Roof and Breakroom Area of the Steam Generator Building, elevation 217 ft. Dynegy Zimmer Power Station, Enerfab employees located on the roof and breakroom area were exposed to a fire and explosion hazard from a hydrogen gas vent line that was venting hydrogen gas during the de-gassing of the steam generator turbine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12503

1910.1200 H01

Deleted Other-than-serious 1 instance 10 exposed
Issued
Oct 10, 2019
Abate by
Nov 14, 2019
Penalty
Initial $1,169 · Current $0 Reduced
29 CFR 1910.1200(h)(1): Employee information and training.  Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and material safety data sheets.  On April 15, 2019, Enerfab employees working at Dynegy Zimmer Power Station, 1781 U.S. 52, Moscow, were not provided with effective information and training on the hazards of hydrogen gas when the steam generator turbine was being de-gassed of hydrogen, and the precautionary measures that needed to be taken to protect their employees during the planned outage.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1169

View Enerfab Power & Industrial, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344279039.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.