OSHA Inspection: ENERFAB POWER & INDUSTRIAL, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ENERFAB POWER & INDUSTRIAL, INC. in 29503 STATE RT. 7, STRATTON, OH 43961 (NAICS 238990). OSHA activity number 345618086.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Enerfab Power & Industrial, INC. — free Get an email when a new federal OSHA severe-injury report for Enerfab Power & Industrial, INC. is published. One employer, no account, unsubscribe in one click.
Site address
29503 STATE RT. 7
City
STRATTON
State
OH
ZIP
43961
Mailing
4955 SPRING GROVE AVENUE, CINCINNATI, OH 45232
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
121
Ownership type
A

2 citations on file for this inspection.

1910.29 E01

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 3, 2022
Abate by
Feb 17, 2022
Penalty
Initial $14,502 · Current $14,502
29 CFR  1910.29(e): Covers. The employer must ensure each cover for a hole in a walking-working surface:  29 CFR  1910.29(e)(1):  Is capable of supporting without failure, at least twice the maximum intended load that may be imposed on the cover at any one time;  a. On or about October 27, 2021 located in the bunker room at 29503 State Rt. 7 Stratton, Ohio, an employer did not use hole covers that could support the weight of employees, therefore  exposing the employees to fall hazards.
Recent events (2)
  • — I (S) $14502
  • — Z (S) $14502

1910.29 E02

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 3, 2022
Abate by
Feb 17, 2022
Penalty
Initial $14,502 · Current $0 Reduced
29 CFR  1910.29(e): Covers. The employer must ensure each cover for a hole in a walking-working surface:  29 CFR  1910.29(e)(2): Is secured to prevent accidental displacement.  a. On or about October 27, 2021 located in the coal conveyor room at 29503 State Rt. 7 Stratton, Ohio, an employer did not secure hole covers to prevent accidental displacement, therefore exposing the employees to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14502

View Enerfab Power & Industrial, INC.'s full OSHA safety record →