Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PURIS PROTEINS, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PURIS PROTEINS, LLC. in 105 SOUTH MAPLE STREET, TURTLE LAKE, WI 54889 (NAICS 311222). OSHA activity number 344279419.

Watch Puris Proteins, LLC. — free Get an email when a new federal OSHA severe-injury report for Puris Proteins, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
105 SOUTH MAPLE STREET
City
TURTLE LAKE
State
WI
ZIP
54889
Mailing
105 SOUTH MAPLE STREET, TURTLE LAKE, WI 54889
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311222
Employees
80
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $9282.00 · Current $6033.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a) Starch drying area; The employer did not develop procedures to isolate energy sources on machines such as but not limited to: peelers, dryers, exhaust fans, rotary sifters, augers and rotary valves.
Recent events (2)
  • — I (S) $6033
  • — Z (S) $9282

1910.147 C07 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees.  (a) Starch drying area; The employer did not provide adequate training on the hazardous energy control program prior to employee(s) performing servicing, cleaning, unjamming and maintenance on equipment such as but not limited to: peeler, dryer, exhaust fans, rotary sifters, rotary valves, and augers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D03

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $9282.00 · Current $6033.00 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):    (a) Starch drying area; All energy isolating devices associated with but not limited to: peelers, dryers, exhaust fans, rotary sifters, rotary valves and augers were not physically located and operated in such a manner as to isolate the machine or equipment from the energy sources during unjamming, cleaning, servicing, and maintenance of equipment.
Recent events (2)
  • — I (S) $6033
  • — Z (S) $9282

1910.147 D04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) Starch drying area; Authorized employee(s) did not affix energy control devices while performing unjamming, cleaning, servicing and maintenance activities to machines such as but no limited to: peelers, dryers, exhaust fans, rotary sifters, rotary valves and augers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $9282.00 · Current $6033.00 Reduced
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible:    (a) Starch drying area; The tri-clover leaf guard enclosing the rotary valve was not secured adequately in that it was easily defeated.
Recent events (2)
  • — I (S) $6033
  • — Z (S) $9282

1910.147 C05 II

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were not singularly identified:  (a) Starch drying area; The lock out lock on the fan creating positive pressure did not bear the authorized employee(s) name.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PURIS PROTEINS, LLC.'s full OSHA safety record →