Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN BUILDERS SUPPLY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AMERICAN BUILDERS SUPPLY, INC. in 100 STONEGATE DR., OCOEE, FL 34761 (NAICS 321214). OSHA activity number 344280953.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Builders Supply, INC. — free Get an email when a new federal OSHA severe-injury report for American Builders Supply, INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 STONEGATE DR.
City
OCOEE
State
FL
ZIP
34761
Mailing
2801 W. AIRPORT BLVD., SANFORD, FL 32771
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321214
Employees
40
Ownership type
A

5 citations on file for this inspection.

1910.178 A06

Other-than-serious 2 instances 5 exposed
Issued
Feb 21, 2020
Abate by
Mar 18, 2020
Penalty
Initial $13,494 · Current $4,250 Reduced
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were maintained in a legible condition:     a. On or about 09/09/2019, at the job site - two forklifts capacity information plates were obstructed because the data plates were covered with a can and a cardboard spool.       b. On or about 09/09/2019, at the job site - the decal safety warnings information of a Piggy Back forklift was obstructed by an electric connector.
Recent events (2)
  • — I (O) $4250
  • — Z (S) $13494

1910.178 L01 I

Other-than-serious 1 instance 5 exposed
Issued
Feb 21, 2020
Abate by
Mar 18, 2020
Penalty
Initial $13,494 · Current $4,250 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a. On or about 09/09/2019, at the job site - employees were exposed to forklift related hazards, in that, employees were allowed to operate forklifts and were not competent or properly trained to operate the forklifts. Employees were not aware of the forklift capacity, and the capacity when forks were elevated or extended out.
Recent events (2)
  • — I (O) $4250
  • — Z (S) $13494

1910.178 L04 II B

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Feb 21, 2020
Abate by
Mar 18, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(ii)(B): 29 CFR 1910.178(l)(4)(ii)(B): Refresher training in relevant topics shall be provided to the operator when; The operator has been involved in an accident or near-miss:  a. On or about 09/09/2019, at the job site - the employer failed to provide training or records of forklift operator recertification after the operator was involved in an accident.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L06

Other-than-serious 1 instance 5 exposed
Issued
Feb 21, 2020
Abate by
Mar 18, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The certification did not include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation:    a. On or about 09/09/2019, at the job site - the employer failed to provide records of forklift operators certification.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.157 C01

Other-than-serious 1 instance 5 exposed
Issued
Feb 21, 2020
Abate by
Mar 18, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a. On or about 09/09/2019, at the entrance of the Operations Manager office - a fire extinguisher was not readily identified.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View American Builders Supply, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344280953.