Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMERICAN BUILDERS SUPPLY, INC. in 6514 PELICAN CREEK CIRCLE, RIVERVIEW, FL 33578 (NAICS 337212). OSHA activity number 346491863.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Builders Supply, INC. — free Get an email when a new federal OSHA severe-injury report for American Builders Supply, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6514 PELICAN CREEK CIRCLE
City
RIVERVIEW
State
FL
ZIP
33578
Mailing
6514 PELICAN CREEK CIRCLE, RIVERVIEW, FL 33578
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337212
Employees
216
Ownership type
A

5 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 10 21 instances 30 exposed
Issued
Apr 27, 2023
Abate by
May 23, 2023
Penalty
Initial $15,625 · Current $10,417 Reduced
29 CFR  1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) On or about and at times before February 8, 2023 at 6514 Pelican Creek Circle RIVERVIEW, FL employees were exposed to release of hazardous energy hazards in that they were instructed to only use the power disconnect switch on the equipment on the F3 line while performing cleaning operations inside of the machinery.
Recent events (2)
  • — I (S) $10417
  • — Z (S) $15625

1910.303 B02

Serious Gravity 10 1 instance 10 exposed
Issued
Apr 27, 2023
Abate by
May 23, 2023
Penalty
Initial $15,625 · Current $10,417 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   (a) On or about and at times before February 8, 2023 at 6514 Pelican Creek Circle RIVERVIEW, FL employees were exposed to electric shock hazards, in that,  permanently mounted fans were plugged into extension cords that had been daisy chained together.
Recent events (2)
  • — I (S) $10417
  • — Z (S) $15625

1910.305 G01 IV A

Serious Gravity 10 3 instances 10 exposed
Issued
Apr 27, 2023
Abate by
Jun 14, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) On or about and at times before February 8, 2023 at 6514 Pelican Creek Circle RIVERVIEW, FL employees were exposed to electric shock hazards, in that, extension cords had been used as permanent wiring to run permanently mounted fans throughout the facility.
Recent events (2)
  • — I (S) $0
  • — Z (S) $15625

1910.303 G02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 27, 2023
Penalty
Initial $15,625 · Current $10,416 Reduced
29 CFR  1910.303(g)(2)(i):Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  (a) On or about and at times before February 8, 2023 at 6514 Pelican Creek Circle RIVERVIEW, FL employees were exposed to electrical hazards, in that, conductors feeding equipment were not fully encased in conduit.
Recent events (2)
  • — I (S) $10416
  • — Z (S) $15625

1910.212 B

Deleted Other-than-serious 2 instances 3 exposed
Issued
Apr 27, 2023
Abate by
May 23, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.212(b):Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  (a) On or about and at times before February 8, 2023 at 6514 Pelican Creek Circle RIVERVIEW, FL employees were exposed to struck by hazards, due to the machines being operated not being permanently anchored.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View American Builders Supply, INC.'s full OSHA safety record →