JEFFERSON, PA —
OSHA Inspection: AMMERAAL BELTECH
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMMERAAL BELTECH in 112 NARDIS DRIVE, JEFFERSON, PA 15344 (NAICS 811310). OSHA activity number 344290549.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMMERAAL BELTECH
- Site address
- 112 NARDIS DRIVE
- City
- JEFFERSON
- State
- PA
- ZIP
- 15344
- Mailing
- 112 NARDIS DRIVE, JEFFERSON, PA 15344
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 46
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Oct 7, 2019
- Abate by
- Nov 25, 2019
- Penalty
- Initial $5,115 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Facility- 112 Nardis Drive, Jefferson, PA: On or about September 6, 2019, the employer failed to develop specific energy control procedures and employees were performing maintenance activities on equipment with multiple energy sources such as but not limited to the skiving machine and waterjet machine.
Recent events (2)
- — I (S) $3000
- — Z (S) $5115
1910.147 C07 I B
- Issued
- Oct 7, 2019
- Abate by
- Nov 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Each affected employee shall be instructed in the purpose and use of the energy control procedure. (a) Facility- 112 Nardis Drive, Jefferson, PA: On or about September 6, 2019, the employer failed to train authorized employees on specific energy control procedures and employees were performing maintenance activities on equipment such as but not limited to the skiving and waterjet machines that contain multiple energy sources.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.242 B
- Issued
- Oct 7, 2019
- Abate by
- Nov 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 P.S.I.: Facility- 112 Nardis Drive, Jefferson, PA: On or about September 6, 2019, employees were using compressed air for cleaning that was not reduced to less than 30 p.s.i.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Ammeraal Beltech
View Ammeraal Beltech's full OSHA safety record →
More inspections in this industry (NAICS 811310)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344290549.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.