Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BLAZER WATERPROOFING SYSTEMS INC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of BLAZER WATERPROOFING SYSTEMS INC in 1022 EAGLES NEST CIRCLE, VAIL, CO 81657 (NAICS 238390). OSHA activity number 344291406.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Blazer Waterproofing Systems INC — free Get an email when a new federal OSHA severe-injury report for Blazer Waterproofing Systems INC is published. One employer, no account, unsubscribe in one click.
Site address
1022 EAGLES NEST CIRCLE
City
VAIL
State
CO
ZIP
81657
Mailing
14102 E SMITH DR STE B, AURORA, CO 80011
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
18
Ownership type
A

4 citations on file for this inspection.

1910.1200 H03 III

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 21, 2019
Abate by
Jan 10, 2020
Penalty
Initial $3,220 · Current $2,250 Reduced
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used:    a) Blazer Waterproofing Systems Inc located at 1022 Eagles Nest Circle, Vail, CO 81657:  On and preceding 9/4/19, the employer training did not include the measures employees could take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used.  An employee was installing waterproofing insulation with a spray adhesive in a 7 foot concrete window well of a multi-family residential foundation with no means of egress and without ventilation equipment.  A flash fire occurred due to an unknown ignition source.  The employee had to self-extricate out of the window well. This condition exposed the employee to chemical and thermal hazards.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3220

1910.1200 G09

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 21, 2019
Abate by
Jan 10, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(9): Where employees must travel between workplaces during a workshift, the employer did not maintain the safety data sheets in each workplace or at the primary workplace facility where employees can immediately obtain information the required information in the case of an emergency:   a) Blazer Waterproofing Systems Inc located at 1022 Eagles Nest Circle, Vail, CO 81657:  On and preceding 9/4/19, the employer had not maintained the safety data sheet in each workplace or at the primary workplace facility where employees can immediately obtain information the required information in the case of an emergency.  An employee was installing waterproofing insulation with a spray adhesive in a 7 foot concrete window well of a multi-family residential foundation with no means of egress and without ventilation equipment. A flash fire occurred due to an unknown ignition source. The employee had to self-extricate out of the well.  This condition exposed employees to chemical and thermal hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1203 A

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 21, 2019
Abate by
Jan 21, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.1203(a): Before it began work at a worksite, the employer did not ensure that a competent person identified all confined spaces in which one or more of the employees it directed may have worked, and/or did not identify each space that was a permit space, through consideration and evaluation of the elements of that space, including testing as necessary:    a) Blazer Waterproofing Systems Inc located at 1022 Eagles Nest Circle, Vail, CO 81657:  On and preceding 9/4/19, before it began work at a worksite, the employer did not ensure that a competent person identified all confined spaces in which one or more of the employees it directed may have worked, and/or did not identify each space that was a permit space, through consideration and evaluation of the elements of that space, including testing as necessary. An employee was installing waterproofing insulation with a spray adhesive in a 7 foot concrete window well of a multi-family residential foundation with no means of egress and without ventilation equipment. A flash fire occurred due to an unknown ignition source. The employee had to self-extricate out of the well. This condition exposed the employee to chemical, thermal, and trapped in hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1051 A

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 21, 2019
Abate by
Jan 10, 2020
Penalty
Initial $3,220 · Current $2,250 Reduced
29 CFR 1926.1051(a): Stairway or ladder was not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided:     a) Blazer Waterproofing Systems Inc located at 1022 Eagles Nest Circle, Vail, CO 81657:  On and preceding 9/4/19, an employee was installing waterproofing insulation with a spray adhesive in a 7 foot concrete window well of a multi-family residential foundation with no means of egress. A flash fire occurred. The employee had to self-extricate out of the well. The employer did not ensure a stairway or ladder was not provided at all personnel points of access where there was a break in elevation of 19 inches. This condition exposed the employee to thermal and trapped in hazards.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3220

View Blazer Waterproofing Systems INC's full OSHA safety record →