LYNN HAVEN, FL —
OSHA Inspection: GAD FRAMING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GAD FRAMING, INC. in 863 CASON CIR. LOT 78, LYNN HAVEN, FL 32444 (NAICS 238160). OSHA activity number 344308077.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GAD FRAMING, INC.
- Site address
- 863 CASON CIR. LOT 78
- City
- LYNN HAVEN
- State
- FL
- ZIP
- 32444
- Mailing
- 4137 CORBIN RD, PANAMA CITY, FL 32405
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.300 B04 II
- Issued
- Dec 4, 2019
- Penalty
- Initial $5,304 · Current $3,182 Reduced
General-duty citation text
29 CFR 1926.300(b)(4)(ii): The point of operation of machine(s) whose operation exposed an employee to injury was not guarded: a. On or about September 13, 2019, employees operating the Makita Circular Saw, s/n 1864327, were exposed to an amputation injury in that the blade guard had been defeated by shimming the sliding guard to the open position.
Recent events (2)
- — I (S) $3182.4
- — Z (S) $5304
1926.416 E01
- Issued
- Dec 4, 2019
- Penalty
- Initial $5,304 · Current $3,182 Reduced
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a. On or about September 13, 2019, employees were exposed to a 120-volt electric shock hazard in that the power cord on the Makita Circular Saw, s/n 1864327, had been damaged and field repaired in two locations, exposing live conductive wires that were not covered with adequate insulative material. b. On or about September 13, 2019, employees were exposed to a 120-volt electric shock hazard from an extension cord connecting the Makita Circular Saw, s/n 1864327, that had been damaged and field repaired, exposing live conductive wires that were not covered with adequate insulative material. c. On or about September 13, 2019, employees were exposed to a 120-volt electric shock hazard in that the power cord on the Makita Circular Saw, s/n 2107609, had been damaged and field repaired, exposing live conductive wires that were not covered with adequate insulative material. d. On or about September 13, 2019, employees were exposed to a 120-volt electric shock hazard in that the power cord on the Makita Circular Saw, s/n 2107910, had been damaged and field repaired in two locations, exposing live conductive wires that were not covered with adequate insulative material. e. On or about September 13, 2019, employees were exposed to a 120-volt electric shock hazard in that plug of the extension cord connecting the Bosch Bulldog Xtreme drill was shattered, exposing live conductors
Recent events (2)
- — I (S) $3182.4
- — Z (S) $5304
1926.501 B13
- Issued
- Dec 4, 2019
- Penalty
- Initial $5,304 · Current $3,182 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On or about September 13, 2019, at the peak of the roof trusses, a framing employee installing hip bracing framing was exposed to a 19 feet fall hazard in that he was not protected by a fall protection system. b. On or about September 13, 2019, over the front entrance, a framing employee installing wood frames was exposed to a 10 feet fall hazard in that he was not protected by a fall protection system.
Recent events (2)
- — I (S) $3182.4
- — Z (S) $5304
1926.1051 A
- Issued
- Dec 4, 2019
- Penalty
- Initial $3,789 · Current $2,273 Reduced
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a. On or about September 13, 2019, in the roof trusses, the employer did not provide ladder access for an employee working on top of the trusses, exposing him to an 19 feet fall hazard.
Recent events (2)
- — I (S) $2273.4
- — Z (S) $3789
1926.1053 B13
- Issued
- Dec 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. On or about September 13, 2019, in the garage, a framing employee was exposed to a 6 feet fall hazard in that he was standing on the second to top step and backside ladder brace of a 6-foot stepladder. b. On or about September 13, 2019, at the northwest corner of the house, a framing employee was exposed to a fall hazard in that he was standing on the top and top step of a 6-foot stepladder.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at GAD Framing, INC.
View GAD Framing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344308077.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.