Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A E M CONSTRUCTION LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of A E M CONSTRUCTION LLC in 2103-2109 ENGELMOHR, HOUSTON, TX 77054 (NAICS 236115). OSHA activity number 344322300.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A E M Construction LLC — free Get an email when a new federal OSHA severe-injury report for A E M Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
2103-2109 ENGELMOHR
City
HOUSTON
State
TX
ZIP
77054
Mailing
20994 BRIAR CHASE DR., PORTER, TX 77365
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
2
Ownership type
A

8 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 16 exposed
Issued
Jan 15, 2020
Abate by
Jan 22, 2020
Penalty
Initial $5,304 · Current $5,304
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):  a) At the construction site, 2103-2109 Engelmohr, Houston, Texas, where inspections of the job site, materials and equipment were not made by a competent persons in that the designated competent persons did not know that they were the designated competent persons and were not familiar with OSHA standards applicable to construction work.
Recent events (1)
  • — Z (S) $5304

1926.150 C01 IV

Serious Gravity 10 32 instances 18 exposed
Issued
Jan 15, 2020
Abate by
Jan 22, 2020
Penalty
Initial $5,304 · Current $5,304
29 CFR 1926.150(c)(1)(iv): There was not at least one fire extinguisher located adjacent to stairways on each floor of a multistory building:  a)  At 2105A Engelmohr, where no fire extinguishers were available inside the town house.  b)  At 2103A Engelmohr, where no fire extinguishers were available inside the town house.  c)  At 2107D Engelmohr, where no fire extinguishers were available inside the town house.  d)  At 2105C Engelmohr, where no fire extinguishers were available inside the town house.  e)  At 2109A Engelmohr, where no fire extinguishers were available inside the town house.  f)  At 2109B Engelmohr, where no fire extinguishers were available inside the town house.  g)  At 2105F Engelmohr, where no fire extinguishers were available inside the town house.  h)  At 2105E Engelmohr, where no fire extinguishers were available inside the town house.
Recent events (1)
  • — Z (S) $5304

1926.1052 C01 II

Serious Gravity 5 12 instances 16 exposed
Issued
Jan 15, 2020
Abate by
Jan 22, 2020
Penalty
Initial $4,546 · Current $4,546
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  a)  At 2103A Engelmohr, where stairway from the third to the fourth floor was not equipped with a stairrail system along its open side.  b)  At 2105A Engelmohr, where the stairway from the first floor to the second floor was not equipped with a stairrail system along its open side.  c)  At 2105C Engelmohr, where the open side of the stairway between the third and fourth floors was not equipped with a stairrail system.  d)  At 2105C Engelmohr, where the open side of the stairway between the second and third floors was not equipped with a stairrail system.  e)  At 2105C Engelmohr, where the open side of the stairway between the first and second floors was not equipped with a stairrail system.  f)  At 2107D Engelmohr, where the open side of the stairs between the third and fourth floors was not equipped with a stairrail.  g)  At 2107D Engelmohr, where the open side of the stairs between the second and third floors was not equipped with a stairrail.  h)  At 2107D Engelmohr, where the open side of the stairs between the first and the second floors was not equipped with a stairrail.  i)  At 2109B Engelmohr, where the open side of the stairs from the first to the second floors lacked a stairrailing.  j)  At 2109B Engelmohr, where the open side of the stairs from the second to third floors lacked a stairrailing.  k)  At 2105E Engelmohr, where the open side of the stairs from the first to the second floors lacked a stairrailing.  l)  At 2105E Engelmohr, where the open side of the stairs from the second to third floors lacked a stairrailing.
Recent events (1)
  • — Z (S) $4546

1926.1052 C04

Serious Gravity 1 2 instances 2 exposed
Issued
Jan 15, 2020
Abate by
Jan 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(4): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stairrail system and the stairway steps:        a)  At 2103A Engelmohr, where no midrail was installed on the stairrail system between the second floor and the third floor.  b)  At 2103A Engelmohr, where no midrail was installed on the stairrail system between the first floor and the second floor.
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 8 instances 16 exposed
Issued
Jan 15, 2020
Abate by
Jan 22, 2020
Penalty
Initial $5,304 · Current $5,304
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:  a)  On or about September 13, 2019, at 2107C Engelmohr, Houston, Texas, where an employee performing roofing work, more than 50 feet above the ground, was not protected from falling by any type of a fall protection system.  b)  At 2103A Engelmohr, where the open side of the second floor was not equipped with a complete guardrail system in that the midrail was missing.  c)  At 2105A Engelmohr, where the open side of the second floor was not equipped with a guardrail system.  d)  At 2105C Engelmohr, where the open side of the second floor was not equipped with a guardrail system.  e)  At 2107D Engelmohr, where the open side of the second floor was not protected by a guardrail system.  f)  At 2109B Engelmohr, where the open side of the second floor was not protected by a guardrail.  g)  At 2109B Engelmohr, where the open side of the third floor was not protected by a guardrail.  h)  At 2105E Engelmohr, where the open side of the second floor was not protected by a guardrail.
Recent events (1)
  • — Z (S) $5304

1926.452 J02

Serious Gravity 10 6 instances 2 exposed
Issued
Jan 15, 2020
Abate by
Jan 22, 2020
Penalty
Initial $5,304 · Current $5,304
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary:  a)  At 2109A Engelmohr, where the poles of pump jack scaffolding were not secured to the structure by rigid triangular bracing at the bottom.  An employee was installing siding from the scaffold, more than 40 feet above the ground.
Recent events (1)
  • — Z (S) $5304

1926.451 B05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 15, 2020
Abate by
Jan 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length extended over its support more than 12 inches and the platform was not designed and installed so that the cantilevered portion of the platform was able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end:  a)  At 2109A Engelmohr, where the platform of a pump jack scaffold on the west side of the townhouse extended over its bearer by approximately 6 feet.
Recent events (1)
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 15, 2020
Abate by
Jan 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:  a)  At 2109A Engelmohr, where employees working from a pump jack scaffold, more than 40 feet above the ground, were not protected from falling by a complete guardrail system.  The midrail had not been installed.
Recent events (1)
  • — Z (S) $0

View A E M Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344322300.