OSHA Inspection: DELTA ARSENAL, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DELTA ARSENAL, LLC in 342 QUINNIPIAC STREET, WALLINGFORD, CT 06492 (NAICS 713990). OSHA activity number 344333273.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Delta Arsenal, LLC — free Get an email when a new federal OSHA severe-injury report for Delta Arsenal, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DELTA ARSENAL, LLC
Site address
342 QUINNIPIAC STREET
City
WALLINGFORD
State
CT
ZIP
06492
Mailing
342 QUINNIPIAC STREET, WALLINGFORD, CT 06492
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713990
Employees
20
Ownership type
A

9 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2019
Abate by
Nov 21, 2019
Penalty
Initial $3,334 · Current $2,210 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition:    WORKSHOP:  The air hose travelling from the wall to the floor behind the Acra turn 1340 lathe was creating a tripping hazard for the employees.
Recent events (2)
  • — I (S) $2210
  • — Z (S) $3334

1910.132 D02

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 8, 2019
Abate by
Dec 30, 2019
Penalty
Initial $3,334 · Current $2,210 Reduced
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done:    WORKSHOP: The employer had not verified through a written certification that the Workplace Hazard Assessment for personal protective equipment (PPE) had been performed as complete.
Recent events (2)
  • — I (S) $2210
  • — Z (S) $3334

1910.132 F01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 8, 2019
Abate by
Dec 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who was required by this section to use personal protective equipment:  WORKSHOP: The employer had not provided training and information to each employee required to wear personal protective equipment (PPE) on the Workplace Hazard Assessment for PPE.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2019
Abate by
Dec 30, 2019
Penalty
Initial $3,334 · Current $2,210 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     WORKSHOP:          1. The rotating chuck of the Acur turn 1340 lathe was unguarded.        2.  The ingoing nip point, created by the lower belt and pulley of the Wilton vertical belt sander was unguarded.
Recent events (2)
  • — I (S) $2210
  • — Z (S) $3334

1910.215 B09

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 8, 2019
Abate by
Dec 30, 2019
Penalty
Initial $3,334 · Current $2,210 Reduced
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:    WORKSHOP:  The AB abrasive grinder was not equipped with tongue guards on both wheels.
Recent events (2)
  • — I (S) $2210
  • — Z (S) $3334

1910.304 F01 IV

Serious Gravity 5 1 instance 8 exposed
Issued
Nov 8, 2019
Penalty
Initial $3,334 · Current $2,210 Reduced
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:    WORKSHOP/BREAK AREA: The 208-volt electrical panel having built-in overcurrent protection devices was blocked by two (2) boxes containing bull eye camera system, sticker tape, and rack roller.
Recent events (2)
  • — I (S) $2210
  • — Z (S) $3334

1910.305 B02

Serious Gravity 1 1 instance 6 exposed
Issued
Nov 8, 2019
Abate by
Dec 30, 2019
Penalty
Initial $2,501 · Current $1,740 Reduced
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    WORKSHOP/HALLWAY:  The outlet box used for the compressor was not equipped with a cover or faceplate.
Recent events (2)
  • — I (S) $1740
  • — Z (S) $2501

1910.305 G01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Nov 8, 2019
Abate by
Dec 30, 2019
Penalty
Initial $3,334 · Current $2,210 Reduced
29 CFR 1910.305(g)(1)(i): Flexible cords and cables were not approved for conditions of use and location:    WORKSHOP/BREAK AREA: The black flexible power cords of the coffee pots, the microwave oven, and the refrigerator were attached to the window frames.
Recent events (2)
  • — I (S) $2210
  • — Z (S) $3334

1910.101 B

Other-than-serious 2 instances 8 exposed
Issued
Nov 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  WORKSHOP/BREAK AREA: The employer had not secured the two (2) carbon dioxide gas cylinders in the break area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Delta Arsenal, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344333273.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.