Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A & A COMPANY, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of A & A COMPANY, INC. in 2700 SOUTH CLINTON AVE., SOUTH PLAINFIELD, NJ 07080 (NAICS 332812). OSHA activity number 344333448.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & a Company, INC. — free Get an email when a new federal OSHA severe-injury report for A & a Company, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
A & A COMPANY, INC.
Site address
2700 SOUTH CLINTON AVE.
City
SOUTH PLAINFIELD
State
NJ
ZIP
07080
Mailing
2700 SOUTH CLINTON AVE., SOUTH PLAINFIELD, NJ 07080
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
23
Ownership type
A

2 citations on file for this inspection.

1910.134 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 13, 2020
Penalty
Initial $3,084 · Current $2,313 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) Thermal spraying department employee(s) were provided and required to use half-face air-purifying respirators without having medical approval through either medical questionnaire or physical exam.  Condition(s) were noted on or about 11/22/2019.
Recent events (2)
  • — I (S) $2313
  • — Z (S) $3084

1910.134 K03

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 13, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:  a) Thermal spraying department employee(s) were provided and required to use half-face air-purifying respirators without having received training, including its fitting & seal check, use, inspection & maintenance, storage, capabilities and limitations,  description of general requirements of the OSHA standard, as well as info on medical signs & symptoms that may limit effectiveness.  Condition(s) were noted on or about 11/22/2019.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View A & a Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344333448.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.