MC COOK, IL —
OSHA Inspection: DARWILL INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DARWILL INC. in 8701 W 47TH ST. SUITE C, MC COOK, IL 60525 (NAICS 323111). OSHA activity number 344340005.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DARWILL INC.
- Site address
- 8701 W 47TH ST. SUITE C
- City
- MC COOK
- State
- IL
- ZIP
- 60525
- Mailing
- 8701 W 47TH ST. SUITE C, MC COOK, IL 60525
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 108
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C07 I B
- Issued
- Jan 9, 2020
- Abate by
- Feb 5, 2020
- Penalty
- Initial $9,472 · Current $6,820 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: a. On or about August 20, 2019, employees operating the Kongskilde Multicutter machine were not provided training on the purpose of the facility's energy control procedure as an affected employee, thereby exposing employees to amputation hazards.
Recent events (2)
- — I (S) $6820
- — Z (S) $9472
1910.147 D
- Issued
- Jan 9, 2020
- Abate by
- Feb 5, 2020
- Penalty
- Initial $13,260 · Current $6,820 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a) Print Room - On or about August 20, 2019, an employee was exposed to machine hazards associated with moving parts when unjamming paper from the Precision AirConvey Corporation, Multicutter. The employer failed to implement energy control application steps as the machine was not shut down or turn off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)((i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $6820
- — Z (S) $13260
More inspections at Darwill INC.
View Darwill INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323111)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344340005.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.