OSHA Inspection: PLATINUM CONTRACTOR CORP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PLATINUM CONTRACTOR CORP in 3450 MAIN ROAD EAST, EMMAUS, PA 18049 (NAICS 238160). OSHA activity number 344348065.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Platinum Contractor Corp — free Get an email when a new federal OSHA severe-injury report for Platinum Contractor Corp is published. One employer, no account, unsubscribe in one click.
Site address
3450 MAIN ROAD EAST
City
EMMAUS
State
PA
ZIP
18049
Mailing
58-60 GARRSION ST 2 FL, NEWARK, NJ 07105
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.451 B05 II

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 18, 2019
Abate by
Oct 30, 2019
Penalty
Initial $2,273 · Current $2,273
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end:  a) 3450 Main Road East, Emmaus, PA, Worksite, Roof - on or about October 1, 2019, employees were performing residential roofing work while using a ladder jack scaffold that had its platform ends extended more than 18 inches beyond its supports.
Recent events (1)
  • — Z (S) $2273

1926.451 F03

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 18, 2019
Abate by
Oct 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:  a) 3450 Main Road East, Emmaus, PA, Worksite, Roof - on or about October 1, 2019, employees were performing residential roofing work while using a ladder jack scaffold with multiple visible deficiencies that had not been inspected by a competent person after being erected and later moved.
Recent events (1)
  • — Z (S) $0

1926.452 K02

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 18, 2019
Abate by
Oct 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.452(k)(2): The support used for ladder jack scaffolds did not meet the requirements of Subpart X - Stairways and Ladders:  a) 3450 Main Road East, Emmaus, PA, Worksite, Roof - on or about October 1, 2019, employees were performing residential roofing work while using a ladder jack scaffold that was supported by a pair of extension ladders that were used at an angle such that the horizontal distance from the top support to the foot of the ladder is in excess of one-quarter of the working length of the ladder.  Abatement Note:  To prevent a ladder from being set too shallow, follow the ladder positioning guidance in accordance with 29 CFR 1926.1053(b)(5)(i).
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 18, 2019
Abate by
Oct 30, 2019
Penalty
Initial $3,978 · Current $3,978
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):   a) 3450 Main Road East, Emmaus, PA, Worksite, Roof - on or about October 1, 2019, employees were performing residential roofing work, approximately 18 feet above grade, without utilizing any means of fall protection.
Recent events (1)
  • — Z (S) $3978

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 18, 2019
Penalty
Initial $2,842 · Current $2,842
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) 3450 Main Road East, Emmaus, PA, Worksite, Roof - on or about October 1, 2019, employees were performing residential roofing work, approximately 18 feet above grade, while accessing the roof by an extension ladder that was not extended at least three feet above the upper landing surface.
Recent events (1)
  • — Z (S) $2842

View Platinum Contractor Corp's full OSHA safety record →