YORK, PA —
OSHA Inspection: YORK REDUCTION SYSTEMS, LP
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of YORK REDUCTION SYSTEMS, LP in 2650 BLACKBRIDGE ROAD, YORK, PA 17406 (NAICS 562920). OSHA activity number 344367123.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- YORK REDUCTION SYSTEMS, LP
- Site address
- 2650 BLACKBRIDGE ROAD
- City
- YORK
- State
- PA
- ZIP
- 17406
- Mailing
- PO BOX 468, EMIGSVILLE, PA 17318
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562920
- Employees
- 14
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.178 L05
- Issued
- Nov 12, 2019
- Penalty
- Initial $2,273 · Current $1,900 Reduced
General-duty citation text
29 CFR 1910.178(l)(5): The employer did not evaluate the competency of the operator who had previously received training appropriate to the truck and working conditions encountered: (a) FACILITY WIDE - The employer did not evaluate powered industrial truck operators to ensure that they were competent to operate the Unicarriers FHD30T5V forklift used within the York Reduction Systems LP facility, on or about October 8, 2019. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1900
- — Z (S) $2273
1910.178 P01
- Issued
- Nov 12, 2019
- Abate by
- Dec 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): (a) PRODUCTION AREA - The Unicarriers FHD30T5V forklift was in need of repair, in that the parking brake was known to be inoperative, and the forklift was not taken out of service and had continued to be used, on or about October 8, 2019. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Nov 12, 2019
- Abate by
- Dec 9, 2019
- Penalty
- Initial $3,031 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour: (a) COMPRESSED GAS CYLINDER STORAGE AREA - The employer stored three oxygen cylinders with two acetylene cylinders in the full cylinder storage area, and two oxygen cylinders with one acetylene cylinder in the empty cylinder storage area, on or about October 8, 2019. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2400
- — Z (S) $3031
1910.303 B02
- Issued
- Nov 12, 2019
- Penalty
- Initial $3,031 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) ACCEPTANCE TESTING AREA - The employer used a six outlet surge protector to provide electricity for a Hercules 4.5 inch seven amp angle grinder and a Black and Decker 1150 watt toaster oven, on or about October 8, 2019. (a) ACCEPTANCE TESTING AREA - The employer used a six outlet surge protector to provide electricity for a Hercules 4.5 inch seven amp angle grinder and a Black and Decker 1150 watt toaster oven, and the surge protector was plugged into an extension cord and then into the wall receptacle, on or about October 8, 2019. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1500
- — Z (S) $3031
1910.178 L06
- Issued
- Nov 12, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): (a) FACILITY WIDE - The employer did not certify that powered industrial truck operators had been trained and evaluated to operate the Unicarriers FHD30T5V forklift used within the York Reduction Systems LP facility, on or about October 8, 2019. No abatement certification or documentation required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at York Reduction Systems, LP
View York Reduction Systems, LP's full OSHA safety record →
More inspections in this industry (NAICS 562920)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344367123.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.