Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPT. OF NAVY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of U.S. DEPT. OF NAVY in BLDG. 137, ASKARS SHOP #69140, SAFE SITE B-10, CHERRY POINT, NC 28533 (NAICS 928110). OSHA activity number 344369053.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Dept. of Navy — free Get an email when a new federal OSHA severe-injury report for U.S. Dept. of Navy is published. One employer, no account, unsubscribe in one click.
Establishment
U.S. DEPT. OF NAVY
Site address
BLDG. 137, ASKARS SHOP #69140, SAFE SITE B-10
City
CHERRY POINT
State
NC
ZIP
28533
Mailing
COMMANDING OFFICER PSC BOX 8021, MCAS CHERRY POINT, CHERRY POINT, NC 28533
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
3900
Ownership type
D

4 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 29, 2019
Abate by
Dec 3, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items A-D of this section:  FRC East, Bldg. Askar Shop #69140, Safe Site B-10:  On or about October 8,  2019, the energy control procedure, for the LSIS 22, failed to clearly identify all of the specific steps to be followed by employees to isolate the stacker lift cage and control the release of stored energy.  The procedure also lacked specific steps to block, clamp or restrain the lift cage along the mast of the machine prior to performing maintenance activity and specific verification steps to take in order to determine the effectiveness of the energy control measures.     ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 29, 2019
Abate by
Dec 3, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  FRC East, Bldg. Askar Shop #69140, Safe Site B-10:  On or about October 8, 2019, the employer did not ensure the periodic inspection and implementation of energy control procedures in order to verify that the procedures being used by authorized employees are adequate and being properly applied.     ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 29, 2019
Abate by
Dec 3, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:    FRC East, Bldg. Askar Shop #69140, Safe Site B-10: On or about October 8, 2019, the employer did not ensure that the training being provided included sufficient detail and specificity to permit an authorized employee to safely and effectively utilize isolating devices such as, brackets and clamps, to control the energy that was unexpectedly released by the lift cage.   ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
  • — Z (S) $0

1910.147 D03

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 29, 2019
Abate by
Dec 3, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  FRC East, Bldg. Askar Shop #69140, Safe Site B-10: On or about October 8, 2019, the attempted servomotor replacement for the LSIS 22 resulting in the unintended release of storage energy from the overhead Lift Cage due to the established energy control procedures not including the specific energy isolating devices that were needed to control the hazardous energy.  Authorized employees were not made aware of the specific isolating devices to be used in order to isolate the equipment from the energy sources, therefore, LOTO devices could not be affixed in accordance with �1910.147(d)(4).  ABATEMENT DOCUMENTATION REQUIERD
Recent events (1)
  • — Z (S) $0

View U.S. Dept. of Navy's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344369053.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.