CHERRY POINT, NC —
OSHA Inspection: U.S. DEPT. OF NAVY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of U.S. DEPT. OF NAVY in BLDG. 137, ASKARS SHOP #69140, SAFE SITE B-10, CHERRY POINT, NC 28533 (NAICS 928110). OSHA activity number 344369053.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. DEPT. OF NAVY
- Site address
- BLDG. 137, ASKARS SHOP #69140, SAFE SITE B-10
- City
- CHERRY POINT
- State
- NC
- ZIP
- 28533
- Mailing
- COMMANDING OFFICER PSC BOX 8021, MCAS CHERRY POINT, CHERRY POINT, NC 28533
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 3900
- Ownership type
- D
Citations
4 citations on file for this inspection.
1910.147 C04 II
- Issued
- Oct 29, 2019
- Abate by
- Dec 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items A-D of this section: FRC East, Bldg. Askar Shop #69140, Safe Site B-10: On or about October 8, 2019, the energy control procedure, for the LSIS 22, failed to clearly identify all of the specific steps to be followed by employees to isolate the stacker lift cage and control the release of stored energy. The procedure also lacked specific steps to block, clamp or restrain the lift cage along the mast of the machine prior to performing maintenance activity and specific verification steps to take in order to determine the effectiveness of the energy control measures. ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $0
1910.147 C06 I
- Issued
- Oct 29, 2019
- Abate by
- Dec 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: FRC East, Bldg. Askar Shop #69140, Safe Site B-10: On or about October 8, 2019, the employer did not ensure the periodic inspection and implementation of energy control procedures in order to verify that the procedures being used by authorized employees are adequate and being properly applied. ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $0
1910.147 C07 I A
- Issued
- Oct 29, 2019
- Abate by
- Dec 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: FRC East, Bldg. Askar Shop #69140, Safe Site B-10: On or about October 8, 2019, the employer did not ensure that the training being provided included sufficient detail and specificity to permit an authorized employee to safely and effectively utilize isolating devices such as, brackets and clamps, to control the energy that was unexpectedly released by the lift cage. ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $0
1910.147 D03
- Issued
- Oct 29, 2019
- Abate by
- Dec 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): FRC East, Bldg. Askar Shop #69140, Safe Site B-10: On or about October 8, 2019, the attempted servomotor replacement for the LSIS 22 resulting in the unintended release of storage energy from the overhead Lift Cage due to the established energy control procedures not including the specific energy isolating devices that were needed to control the hazardous energy. Authorized employees were not made aware of the specific isolating devices to be used in order to isolate the equipment from the energy sources, therefore, LOTO devices could not be affixed in accordance with �1910.147(d)(4). ABATEMENT DOCUMENTATION REQUIERD
Recent events (1)
- — Z (S) $0
More inspections at U.S. Dept. of Navy
View U.S. Dept. of Navy's full OSHA safety record →
More inspections in this industry (NAICS 928110)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344369053.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.