ELGIN, IL —
OSHA Inspection: COLONY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of COLONY, INC. in 2500 GALVIN DR., ELGIN, IL 60124 (NAICS 339999). OSHA activity number 344386503.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COLONY, INC.
- Site address
- 2500 GALVIN DR.
- City
- ELGIN
- State
- IL
- ZIP
- 60124
- Mailing
- 2500 GALVIN DR., ELGIN, IL 60124
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339999
- Employees
- 250
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C07 I
- Issued
- Mar 25, 2020
- Abate by
- May 31, 2020
- Penalty
- Initial $13,494 · Current $9,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: Woodworking Dept., Schelling fh4 Cut-to-Size Saw #39. On or about October 3, 2019 through March 11, 2020, machine operators who performed servicing and maintenance tasks such as blade changes and cleaning of saw dust in the saw blade area were exposed to amputation and crushing hazards to hands and fingers in the event of unexpected start up and release of stored energy of the rotating blades and blade motor carriage. The employer did not ensure that lockout/tagout training, including a method for controlling movement of the blade carriage due to energy release, was provided to all employees who were assigned such tasks, to ensure that the purpose and function of the energy control program were understood by employees and that the knowledge and skills required for the safe application, usage and removal of the energy controls were acquired by employees. Abatement documentation is required for this item in accordance with the requirements of 1903.19(d).
Recent events (2)
- — I (S) $9500
- — Z (S) $13494
1910.147 D
- Issued
- Mar 25, 2020
- Abate by
- May 31, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): Woodworking Dept., Schelling fh4 Cut-to-Size Saw #39. On or about October 3, 2019 through March 11, 2020, machine operators who performed servicing and maintenance tasks such as saw blade changes and cleaning of saw dust inside the saw blade and blade motor area of the machine, were exposed to amputation and crushing hazards to hands and fingers from unexpected startup and/or release of stored energy. Employees were instructed to use computer controls to over-ride a safety switch on the access door to the blade area as well as to activate an emergency stop button prior to entering the blade area danger zone and were not required to deenergize and lockout the machine's electrical and pneumatic energy sources. Employees were not required to control hazardous energy sources in the following sequence: 1) turn off and shut down the machines, 2) physically locate and operate energy isolating devices in such a manner as to isolate the machines or equipment from the energy source(s), 3) affix lockout or tagout devices to each energy isolating device, 4) relieve, disconnect, restrain and otherwise render safe all hazardous residual or stored energy, 5) verify that isolation and de-energization of the machines or equipment have been accomplished. Alternative protections, such as machine guarding, were not utilized. Abatement documentation is required for this item in accordance with the requirements of 1903.19(d).
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Colony, INC.
View Colony, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 339999)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344386503.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.