OSHA Inspection: PRIME BUILDERS CONSTRUCTION GROUP, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRIME BUILDERS CONSTRUCTION GROUP, INC. in 209 4TH STREET, WILMETTE, IL 60091 (NAICS 238130). OSHA activity number 344405105.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Prime Builders Construction Group, INC. — free Get an email when a new federal OSHA severe-injury report for Prime Builders Construction Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
209 4TH STREET
City
WILMETTE
State
IL
ZIP
60091
Mailing
4432 N. ORIOLE AVE., NORRIDGE, IL 60706
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 21, 2019
Abate by
Nov 27, 2019
Penalty
Initial $2,273 · Current $1,000 Reduced
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:        a) On or about October 24, 2019, employees were exposed to eye injury while operating a pneumatic nailer to fasten rafters on a second story/attic deck without eye protection.     b) On or about October 24, 2019, employees were exposed to eye injury while operating an electric saw to cut lumber on the ground level without eye protection.        In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2273

1926.416 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 21, 2019
Abate by
Nov 27, 2019
Penalty
Initial $2,273 · Current $1,000 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:           a) On or about October 24, 2019, employees were exposed to electrical hazards where carpentry work was conducted adjacent to 120/240 volt, 200 amp electrical powerline service drop.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2273

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 21, 2019
Abate by
Nov 27, 2019
Penalty
Initial $3,978 · Current $2,000 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):                      a) On or about November 24, 2019, employees were exposed to the hazard of falling approximately 20 feet to the exterior of the building while working from the top plate and deck of the second story/attic without the benefit of fall protection.                   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3978

1926.1053 B12

Serious Gravity 5 4 instances 4 exposed
Issued
Nov 21, 2019
Abate by
Nov 27, 2019
Penalty
Initial $2,273 · Current $1,000 Reduced
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive side-rails:       a) On or about October 24, 2019, during carpentry work, a portable aluminum extension ladder was provided for employee use where the ladder or the employees could contact a 120/240 volt, 200 amp electrical powerline service drop.        In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2273

View Prime Builders Construction Group, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344405105.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.