OSHA Inspection: BUCKEYE BODY AND EQUIPMENT (BUCKEYE TRUCK EQUIPMENT INC)
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of BUCKEYE BODY AND EQUIPMENT (BUCKEYE TRUCK EQUIPMENT INC) in 939 E. STARR AVENUE, COLUMBUS, OH 43201 (NAICS 336211). OSHA activity number 344408844.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 939 E. STARR AVENUE
- City
- COLUMBUS
- State
- OH
- ZIP
- 43201
- Mailing
- P.O. BOX 1150, COLUMBUS, OH 43216
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336211
- Employees
- 32
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.106 D04 I
- Issued
- Jan 15, 2020
- Abate by
- Feb 20, 2020
- Penalty
- Initial $6,630 · Current $4,641 Reduced
General-duty citation text
29 CFR 1910.106(d)(4)(i): "Construction." Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which drains to a safe location. Where other portions of the building or other properties are exposed, windows shall be protected as set forth in the Standard for Fire Doors and Windows, NFPA No. 80-1968, which is incorporated by reference as specified in Sec. 1910.6, for Class E or F openings. Wood at least 1 inch nominal thickness may be used for shelving, racks, dunnage, scuffboards, floor overlay, and similar installations. a. On and/or before October 24, 2019, the inside door for the flammable liquid material storage room (materials storage #2) located in building 2 did not have an approved self-closing fire door. b. On and/or before October 24, 2019, the outside double doors for the flammable liquid material storage room (materials storage #2) located in building 2 did not have approved self-closing fire doors.
Recent events (2)
- — I (S) $4641
- — Z (S) $6630
1910.107 G07
- Issued
- Jan 15, 2020
- Abate by
- Feb 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(7): "No Smoking" signs. "No smoking" signs in large letters on contrasting color background shall be conspicuously posted at all spraying areas and paint storage rooms. a. On and/or before October 24, 2019, the flammable liquid material storage room (materials storage #2) located in building 2 did not have a "No Smoking" sign conspicuously posted in the area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- Jan 15, 2020
- Abate by
- Feb 20, 2020
- Penalty
- Initial $3,978 · Current $2,785 Reduced
00400440167524602590
General-duty citation text
29 CFR 1910.134(e)(1): General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator. a. On and/or before October 24, 2019, in the paint area of building 2, the employer did not provide medical evaluations for employees required to wear 3M 5300 half-facepiece respirators w/ organic vapor cartridges & P95 pre-filters while painting and performing other activities in the paint booths and/or mix room.
Recent events (2)
- — I (S) $2784.6
- — Z (S) $3978
1910.134 C01
- Issued
- Jan 15, 2020
- Abate by
- Feb 20, 2020
- Penalty
- Initial $0 · Current $0
00400440167524602590
General-duty citation text
29 CFR 1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer shall establish and implement a written respiratory protection program with worksite-specific procedures. The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use. The employer shall include in the program the following provisions of this section, as applicable: 29 CFR 1910.134(c)(1) through 1910.134(c)(ix). a. On and/or before October 24, 2019, the employer did not establish and implement a written respiratory protection program with worksite-specific procedures for employees required to use tight-fitting facepiece respirators while painting and performing other activities in the paint booths and/or mix room.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 F02
- Issued
- Jan 15, 2020
- Abate by
- Feb 20, 2020
- Penalty
- Initial $0 · Current $0
00400440167524602590
General-duty citation text
29 CFR 1910.134(f)(2): The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter. a. On and/or before October 24, 2019, in the paint area of building 2, the employer did not ensure that employees required to use 3M 5300 half-facepiece respirators w/ organic vapor cartridges & P95 pre-filters while painting and performing other activities in the paint booths and/or mix room were fit tested prior to initial use of the respirators.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 G01 I A
- Issued
- Jan 15, 2020
- Abate by
- Jan 28, 2020
- Penalty
- Initial $0 · Current $0
00400440167524602590
General-duty citation text
29 CFR 1910.134(g)(1)(i): The employer shall not permit respirators with tight-fitting facepieces to be worn by employees who have: 29 CFR 1910.134(g)(1)(i)(A): Facial hair that comes between the sealing surface of the facepiece and the face or that interferes with valve function. a. On and/or before October 24, 2019, in the paint area of building 2, the employer did not ensure that an employee required to use a 3M 5300 half-facepiece respirator w/ organic vapor cartridges & P95 pre-filters while painting and performing other activities in the paint booths and/or mix room was clean-shaven with no facial hair coming between the sealing surface of the respirator and face.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 K03
- Issued
- Jan 15, 2020
- Abate by
- Feb 20, 2020
- Penalty
- Initial $0 · Current $0
00400440167524602590
General-duty citation text
29 CFR 1910.134(k)(3): The employer shall provide the training prior to requiring the employee to use a respirator in the workplace. a. On and/or before October 24, 2019, in the paint area of building 2, the employer did not provide training on respiratory protection for employees required to use 3M 5300 half-facepiece respirators w/ organic vapor cartridges & P95 pre-filters while painting and performing other activities in the paint booths and/or mix room.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Buckeye Body and Equipment (Buckeye Truck Equipment INC)
View Buckeye Body and Equipment (Buckeye Truck Equipment INC)'s full OSHA safety record →
More inspections in this industry (NAICS 336211)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344408844.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.