CUMMING, GA —
OSHA Inspection: PANDUIT CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PANDUIT CORPORATION in 1819 ATLANTA HWY., CUMMING, GA 30040 (NAICS 335932). OSHA activity number 344410030.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PANDUIT CORPORATION
- Site address
- 1819 ATLANTA HWY.
- City
- CUMMING
- State
- GA
- ZIP
- 30040
- Mailing
- 1819 ATLANTA HWY., CUMMING, GA 30040
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335932
- Employees
- 100
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Nov 6, 2019
- Abate by
- Dec 4, 2019
- Penalty
- Initial $6,440 · Current $3,864 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. 1819 Atlanta Hwy. Cumming, GA (Extrusion Line #2 Vulcan Coiler) - The employees (ZCM 1000 electric tape dispenser operators) were exposed to sudden energization or start-up of the single energy source machines by not unplugging the cord before maintenance is being performed (clearing the tape jam). The employer did not have machine specific procedures for the single energy source electric tape dispenser (cord and plug). The employees were not disconnecting/unplugging the machine which is equivalent to lockout/tagout before servicing/maintenance, on or about 10/29/19. Note: The exception to 29 CFR 1910.147(c)(4)(i) was not followed in its entirety.
Recent events (2)
- — I (S) $3864
- — Z (S) $6440
1910.147 C07 I A
- Issued
- Nov 6, 2019
- Abate by
- Dec 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee had not received training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: a. 1819 Atlanta Hwy. Cumming, GA (Extrusion Line #2 Vulcan Coiler) - The employees (ZCM 1000 electric tape dispenser operators) were exposed to sudden energization or start-up of the single energy source machines by not unplugging the cord before maintenance is being performed (clearing the tape jam). The machine (electric tape dispenser) operators were not provided with training on the hazardous conditions when failed to disconnect/unplugged the single energy source which is equivalent to lockout/tagout on the electric tape dispenser, on or about 1029/19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Panduit Corporation
View Panduit Corporation's full OSHA safety record →
More inspections in this industry (NAICS 335932)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344410030.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.