Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PURCELL P & C LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of PURCELL P & C LLC in SASA VALLEY RVP U4 VALVE PIT REPAIRS NAVAL BASE GUAM, PITI, GU 96915 (NAICS 238320). OSHA activity number 344414693.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Purcell P & C LLC — free Get an email when a new federal OSHA severe-injury report for Purcell P & C LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PURCELL P & C LLC
Site address
SASA VALLEY RVP U4 VALVE PIT REPAIRS NAVAL BASE GUAM
City
PITI
State
GU
ZIP
96915
Mailing
6456 S 144TH ST, TUKWILA, WA 98168
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
146
Ownership type
A

5 citations on file for this inspection.

1910.134 E06 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 31, 2020
Abate by
Feb 20, 2020
Penalty
Initial $4,424 · Current $3,097 Reduced
29 CFR 1910.134(e)(6)(i): The employer did not obtain a written recommendation from a physician or other licensed health care professional regarding the employee's ability to use a respirator:  (Construction Reference: 1926.103)   Guam Naval Base Valve Pit U4: A medical evaluation was not completed for at least one employee wearing a respirator.  Employee was exposed to respiratory hazards.
Recent events (2)
  • — I (S) $3096.8
  • — Z (S) $4424

1910.134 F02

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 31, 2020
Abate by
Feb 27, 2020
Penalty
Initial $4,424 · Current $3,097 Reduced
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested whenever a different respirator facepiece (size, style, model or make) was used:  (Construction Reference: 1926.103)  Guam Naval Base Valve Pit U4:  Employees were wearing North brand full and half-mask respirators without fit tests.  Fit tests were provided with 3M half-mask respirators.  Employees were exposed to respiratory hazards.
Recent events (2)
  • — I (S) $3096.8
  • — Z (S) $4424

1910.134 G01 I A

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 31, 2020
Abate by
Feb 12, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:  (Construction Reference: 1926.103)  Guam Naval Base Valve Pit U4:  An employee with facial hair was wearing a dual cartridge tight fitting respirator while painting on a valve.  The employee was exposed to respiratory hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H04 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 31, 2020
Abate by
Feb 12, 2020
Penalty
Initial $4,424 · Current $3,097 Reduced
29 CFR 1910.134(h)(4)(i): Respirators that failed an inspection or were otherwise found to be defective were not removed from service and discarded or repaired only by persons appropriately trained to perform such operations:  (Construction Reference: 1926.103)  Guam Naval Base Valve Pit U4:  The Honeywell full face respirator valve had been repaired with tape.  Employees were exposed to respiratory hazards.
Recent events (2)
  • — I (S) $3096.8
  • — Z (S) $4424

1910.134 H01

Other-than-serious 1 instance 3 exposed
Issued
Jan 31, 2020
Abate by
Feb 12, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(1): Respirators were not cleaned and disinfected using the procedures in Appendix B-2 of 29 CFR 1910.134 or equivalent procedures recommended by the respirator manufacturer:  (Construction Reference: 1926.103)  Guam Naval Base Valve Pit U4:  Respirators were not cleaned and disinfected properly.  Employees used rags to clean their respirators because the respirator wipes were not available.  Employees were exposed to inhalation hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Purcell P & C LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344414693.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.