Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORTHERN REPAIR & WELDING

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NORTHERN REPAIR & WELDING in 169955 RINGLE AVE, RINGLE, WI 54471 (NAICS 811310). OSHA activity number 344423462.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Northern Repair & Welding — free Get an email when a new federal OSHA severe-injury report for Northern Repair & Welding is published. One employer, no account, unsubscribe in one click.
Site address
169955 RINGLE AVE
City
RINGLE
State
WI
ZIP
54471
Mailing
169955 RINGLE AVE, RINGLE, WI 54471
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
19
Ownership type
A

4 citations on file for this inspection.

1910.178 L04 III

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 21, 2020
Abate by
Apr 10, 2020
Penalty
Initial $2,545 · Current $1,527 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.    During the month of November 2019 and thereafter, the employer did not re-evaluate each authorized forklift operator at least once every three years to ensure they had the skills and knowledge necessary to operate safely.
Recent events (2)
  • — I (S) $1527
  • — Z (S) $2545

1910.178 L06

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 21, 2020
Abate by
Apr 10, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.  During the month of November 2019 and thereafter, the employer did not certify that each operator, who had previously received training and that such training was appropriate to the truck and working conditions encountered, were evaluated and found competent to operate the forklift safely.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.254 D09 III

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 21, 2020
Abate by
Mar 20, 2020
Penalty
Initial $5,089 · Current $3,053 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors shall be replaced. Joining lengths of work and electrode cables shall be done by the use of connecting means specifically intended for the purpose. The connecting means shall have insulation adequate for the service conditions.     During the month of November 2019 and thereafter, the Hypertherm Powermax 85 had a damaged cable exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $3053.3
  • — Z (S) $5089

1910.334 A02 II

Serious Gravity 5 7 instances 8 exposed
Issued
Feb 21, 2020
Abate by
Mar 20, 2020
Penalty
Initial $5,089 · Current $3,053 Reduced
29 CFR 1910.334(a)(2)(ii): If there is a defect or evidence of damage that might expose an employee to injury, the defective or damaged item shall be removed from service, and no employee may use it until repairs and tests necessary to render the equipment safe have been made.    (a)  During the month of November 2019 and thereafter, the electrical power cord used with the Miller Millermatic 350P welders had a missing grounding prong and had electrical tape around the plug and was not removed from service exposing employees to electrical shock hazards.    (b)  During the month of November 2019 and thereafter, the electrical power cord used with the Miller Millermatic 252 welders had a missing grounding prong and had electrical tape around the plug and was not removed from service exposing employees to electrical shock hazards.    (c)  During the month of November 2019 and thereafter, the Ellis horizontal bandsaw had a missing grounding prong and was not removed from service exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $3053.3
  • — Z (S) $5089

View Northern Repair & Welding's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344423462.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.