NORFOLK, VA —
OSHA Inspection: DIAMOND EQUIPMENT CONTRACTING CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DIAMOND EQUIPMENT CONTRACTING CORPORATION in 200 GRANBY STREET, NORFOLK, VA 23510 (NAICS 238990). OSHA activity number 344425467.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DIAMOND EQUIPMENT CONTRACTING CORPORATION
- Site address
- 200 GRANBY STREET
- City
- NORFOLK
- State
- VA
- ZIP
- 23510
- Mailing
- 520 CENTRAL DRIVE STE 104, VIRGINIA BEACH, VA 23454
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 24
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.404 B01 II
- Issued
- Mar 12, 2020
- Abate by
- Apr 7, 2020
- Penalty
- Initial $4,626 · Current $3,238 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection.: a) Norfolk Federal Building, Atrium: On or about 11/05/2019, employees used an extension cord plugged into permanent power to supply power to a hammer drill, bore machine and water pump without a ground fault circuit interrupter device as a result employees were potentially exposed to a shock hazard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3238.2
- — Z (S) $4626
1926.404 F06
- Issued
- Mar 12, 2020
- Abate by
- Apr 7, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Norfolk Federal Building, Atrium: On or about 11/05/2019, the path to ground on the hammer drill was not permanent and continuous in that the male attachment plug was missing the ground prong without the protection of a GFCI device. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 G02 IV
- Issued
- Mar 12, 2020
- Abate by
- Apr 7, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Norfolk Federal Building, Atrium: On or about 11/05/2019, the wiring that entered into the switch box was not provided with stain relief in that the 90-degree flexible metal conduit connector was pulled away from the box, as a result employees were exposed to a potential electrical shock hazard without the protection of a GFCI device. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Mar 12, 2020
- Abate by
- Apr 7, 2020
- Penalty
- Initial $3,856 · Current $2,699 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Norfolk Federal Building: On or about 11/05/2019, CSHO observed two employees on the roof of the atrium approximately 4ft from an unguarded edge without fall protection, as a result employees were exposed to a 32ft fall hazard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2699.2
- — Z (S) $3856
More inspections at Diamond Equipment Contracting Corporation
View Diamond Equipment Contracting Corporation's full OSHA safety record →
More inspections in this industry (NAICS 238990)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344425467.