Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INDUSTRIAL LIGHTING PRODUCTS, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of INDUSTRIAL LIGHTING PRODUCTS, LLC in 519 CODISCO WAY, SANFORD, FL 32771 (NAICS 335122). OSHA activity number 344430061.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Industrial Lighting Products, LLC — free Get an email when a new federal OSHA severe-injury report for Industrial Lighting Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
519 CODISCO WAY
City
SANFORD
State
FL
ZIP
32771
Mailing
519 CODISCO WAY, SANFORD, FL 32771
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335122
Employees
225
Ownership type
A

1 citation on file for this inspection.

1910.95 C01

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 27, 2020
Abate by
Mar 24, 2020
Penalty
Initial $12,145 · Current $7,287 Reduced
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:   a. At the sheet metal processing area located at 529 Codisco Way in Sanford FL, the Amada Queen PEGA-345 operator was exposed to continuous noise levels at 47.29 % of the allowable 8 hour TWA-Action Limit (85 dBA).  The equivalent dBA level of 47.29 % is 84.6 dBA.  The sampling was performed for 594 minutes during one shift on December 11, 2019.    NOTE: The 8-hour TWA sound level of 85 dBA that triggers the requirement of a hearing conservation program (HCP) can be adjusted for work shifts less than or longer than 8 hours. When making the adjustment, the following formula is used: AL=90 + 16.1 x Log [50/{12.5(hours)]. Affected employee was exposed to continuous noise level over 594 minutes work shift. Therefore, the TWA sound level that triggers the requirement for a HCP was reduced to 82.1 dBA.
Recent events (2)
  • — I (S) $7287
  • — Z (S) $12145

View Industrial Lighting Products, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344430061.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.