HOUSTON, TX —
OSHA Inspection: CREATIVE SPECIALTY FOOD SOLUTIONS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CREATIVE SPECIALTY FOOD SOLUTIONS, LLC in 3713 JENSEN DR., HOUSTON, TX 77026 (NAICS 311412). OSHA activity number 344434881.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CREATIVE SPECIALTY FOOD SOLUTIONS, LLC
- Site address
- 3713 JENSEN DR.
- City
- HOUSTON
- State
- TX
- ZIP
- 77026
- Mailing
- 3715 JENSEN DR., HOUSTON, TX 77026
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311412
- Employees
- 130
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.215 A02
- Issued
- Dec 3, 2019
- Abate by
- Dec 20, 2019
- Penalty
- Initial $7,501 · Current $4,501 Reduced
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: On or about November 4, 2019, and times prior thereto, in the Maintenance Area where employees were exposed to a struck-by hazard when operating a bench grinder without a safety guard over the spindle end and nut.
Recent events (2)
- — I (S) $4500.6
- — Z (S) $7501
1910.215 A04
- Issued
- Dec 3, 2019
- Abate by
- Dec 20, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): On offhand grinding machines, work rests were not used to support the work and/or were not kept adjusted closely to the wheel with a maximum opening of one-eighth inch: On or about November 4, 2019, and times prior thereto, in the Maintenance Area where employees were exposed to a struck-by hazard when operating a bench grinder without a work rest adjusted with a maximum opening of one-eight inch.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 B09
- Issued
- Dec 3, 2019
- Abate by
- Dec 20, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: On or about November 4, 2019, and times prior thereto, in the Maintenance Area where employees were exposed to a struck-by hazard when operating a bench grinder without a tongue guard installed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 F01 V
- Issued
- Dec 3, 2019
- Abate by
- Dec 20, 2019
- Penalty
- Initial $13,127 · Current $7,876 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(v): Fuses and circuit breakers for circuits rated 600 volts, nominal, or less were not located or shielded so that employees would not be burned or otherwise injured by their operation: On or about November 4, 2019, and times prior thereto, in the Maintenance Area where employees were exposed to an electrical shock hazard when operating a Lincoln Welder wired to a knife switch with the energized fuses exposed.
Recent events (2)
- — I (S) $7876.2
- — Z (S) $13127
1910.305 G01 IV A
- Issued
- Dec 3, 2019
- Abate by
- Dec 20, 2019
- Penalty
- Initial $13,127 · Current $7,876 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about November 4, 2019, and time prior thereto: a. On the NE wall of the Maintenance Leads Office, where employees were exposed to electrical shock hazards when an electrical cord was wired into the terminal ends of a 240-VAC knife switch and used as a substitute for fixed wiring. b. Inside the Maintenance Leads Office on the north wall, where employees were exposed to electrical shock hazards when an electrical cord was installed inside a 110-VAC wall outlet and used as a substitute for fixed wiring. .
Recent events (2)
- — I (S) $7876.2
- — Z (S) $13127
1910.305 G01 IV B
- Issued
- Dec 3, 2019
- Abate by
- Dec 20, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used to run through holes in walls, ceilings, or floors. On or about November 4, 2019, and time prior thereto, in the Maintenance Lead's Office on the north wall, where employees were exposed to fire hazards when an electrical cord was run through a drilled hole in the wall.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Dec 3, 2019
- Abate by
- Dec 20, 2019
- Penalty
- Initial $374 · Current $224 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: On or about November 4, 2019, and times prior thereto: a. In the Tamale Production on the Line B conveyor where a flexible cable was not connected to the device to provide strain relief. b. In the Kitchen Area on a Masa Mixer where a flexible cable was not connected to the device to provide strain relief. CREATIVE SPECIALTY FOOD SOLUTIONS, LLC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.305(G)(2)(III), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1270983, CITATION NUMBER 1, ITEM NUMBER 3, AND WAS AFFIRMED AS A FINAL ORDER ON NOVEMBER 28, 2017, WITH A FINAL ABATEMENT DATE OF NOVEMBER 20, 2017, WITH RESPECT TO A WORKPLACE LOCATED 3713 JENSEN DRIVE, HOUSTON, TX 77026.
Recent events (2)
- — I (R) $224.4
- — Z (R) $374
More inspections at Creative Specialty Food Solutions, LLC
View Creative Specialty Food Solutions, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311412)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344434881.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.