HEARNE, TX —
OSHA Inspection: PANEL TRUSS HEARNE, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PANEL TRUSS HEARNE, LLC in 407 WEST 6TH STREET, HEARNE, TX 77859 (NAICS 321214). OSHA activity number 344437405.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PANEL TRUSS HEARNE, LLC
- Site address
- 407 WEST 6TH STREET
- City
- HEARNE
- State
- TX
- ZIP
- 77859
- Mailing
- P.O. BOX 1007, HENDERSON, TX 75653
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321214
- Employees
- 43
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Jan 8, 2020
- Abate by
- Feb 11, 2020
- Penalty
- Initial $4,508 · Current $2,705 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about September 9, 2019 an employee engaged in wooden truss building operations was operating Floor Truss Table #8 when a pneumatic clamp was engaged while the employees left hand was still positioned on the wooden truss, exposing employee to the hazard of being pinched by floor truss clamps.
Recent events (2)
- — I (S) $2704.8
- — Z (S) $4508
1910.219 C04 I
- Issued
- Jan 8, 2020
- Abate by
- Feb 11, 2020
- Penalty
- Initial $3,978 · Current $2,387 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: On or about November 6, 2019 and at times prior thereto, power-transmission conveyor roller's had unguarded projecting shaft ends that varied in lengths that were 1.5 times the length of the shaft ends diameter, exposing employee's to the hazard of getting caught in conveyor rollers with projecting shaft ends.
Recent events (2)
- — I (S) $2386.8
- — Z (S) $3978
More inspections at Panel Truss Hearne, LLC
View Panel Truss Hearne, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321214)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344437405.