WENTZVILLE, MO —
OSHA Inspection: GM WENTZVILLE ASSEMBLY CENTER
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GM WENTZVILLE ASSEMBLY CENTER in 1500 EAST HWY A, WENTZVILLE, MO 63385 (NAICS 336112). OSHA activity number 344446190.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GM WENTZVILLE ASSEMBLY CENTER
- Site address
- 1500 EAST HWY A
- City
- WENTZVILLE
- State
- MO
- ZIP
- 63385
- Mailing
- 1500 EAST HWY A, WENTZVILLE, MO 63385
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336112
- Employees
- 4400
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C06 I
- Issued
- Nov 27, 2019
- Abate by
- Jan 16, 2020
- Penalty
- Initial $13,260 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about 11/11/2019, GM Wentzville Assembly Center, located at 1500 East Hwy A, Wentzville, MO, did not conduct a complete periodic inspections of their Energy Control Program. An employee had an incident that severed his index, middle and ring fingers on his left hand. The victims last completed periodic inspection was dated back on 09/27/2018.
Recent events (2)
- — I (S) $0
- — Z (S) $13260
1910.147 D04 I
- Issued
- Nov 27, 2019
- Abate by
- Jan 16, 2020
- Penalty
- Initial $9,472 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about 11/11/2019, GM Wentzville Assembly Center, located at 1500 East Hwy A, Wentzville, MO, had an employee/victim that did not have a lock on the electric box for the Stage #1 Phosphate Entrance Air Seal Fan system while performing Millwright (maintenance) work.
Recent events (2)
- — I (S) $0
- — Z (S) $9472
More inspections at GM Wentzville Assembly Center
View GM Wentzville Assembly Center's full OSHA safety record →
More inspections in this industry (NAICS 336112)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344446190.