Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GM WENTZVILLE ASSEMBLY CENTER

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GM WENTZVILLE ASSEMBLY CENTER in 1500 EAST HWY A, WENTZVILLE, MO 63385 (NAICS 336112). OSHA activity number 344446190.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GM Wentzville Assembly Center — free Get an email when a new federal OSHA severe-injury report for GM Wentzville Assembly Center is published. One employer, no account, unsubscribe in one click.
Site address
1500 EAST HWY A
City
WENTZVILLE
State
MO
ZIP
63385
Mailing
1500 EAST HWY A, WENTZVILLE, MO 63385
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336112
Employees
4400
Ownership type
A

2 citations on file for this inspection.

1910.147 C06 I

Deleted Serious Gravity 10 1 instance 50 exposed
Issued
Nov 27, 2019
Abate by
Jan 16, 2020
Penalty
Initial $13,260 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  On or about 11/11/2019, GM Wentzville Assembly Center, located at 1500 East Hwy A, Wentzville, MO, did not conduct a complete periodic inspections of their Energy Control Program.  An employee had an incident that severed his index, middle and ring fingers on his left hand.  The victims last completed periodic inspection was dated back on 09/27/2018.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13260

1910.147 D04 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Nov 27, 2019
Abate by
Jan 16, 2020
Penalty
Initial $9,472 · Current $0 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:   On or about 11/11/2019, GM Wentzville Assembly Center, located at 1500 East Hwy A, Wentzville, MO, had an employee/victim that did not have a lock on the electric box for the Stage #1 Phosphate Entrance Air Seal Fan system while performing Millwright (maintenance) work.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9472

View GM Wentzville Assembly Center's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344446190.