Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: S.E.K. CONSTRUCTION, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of S.E.K. CONSTRUCTION, LLC in 1800 ELMERTON AVENUE, HARRISBURG, PA 17110 (NAICS 238120). OSHA activity number 344466040.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S.E.K. Construction, LLC — free Get an email when a new federal OSHA severe-injury report for S.E.K. Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1800 ELMERTON AVENUE
City
HARRISBURG
State
PA
ZIP
17110
Mailing
1361 BRIERTOWN ROAD, EAST EARL, PA 17519
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 5, 2020
Abate by
Mar 3, 2020
Penalty
Initial $3,856 · Current $2,699 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person:    (a) Front of the Pennsylvania State Police Headquarters Building - The competent person did not ensure the correct use of all components of personal fall arrest systems as evidenced by the fact that an employee used a FallTech self-retracting lifeline, model 7276WR, for tying off in an aerial lift even though FallTech did not approve this fall protection component for use in aerial lifts, exposing the employee to a fall hazard, on or about November 21, 2019.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2699.2
  • — Z (S) $3856

1926.95 C

Other-than-serious 1 instance 1 exposed
Issued
Feb 5, 2020
Abate by
Mar 3, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.95(c): Personal protective equipment was not of safe design and construction for the work to be performed:    (a) Front of the Pennsylvania State Police Headquarters Building - An employee, working from a JLG aerial lift to install horizontal supports for the curtain wall between the second and third story, used a FallTech self-retracting lifeline, model 7276WR, for tying off to the aerial lift.  FallTech did not design and approve this fall protection component for use in aerial lifts, exposing the employee to a fall hazard, on or about November 21, 2019.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.502 D21

Other-than-serious 1 instance 1 exposed
Issued
Feb 5, 2020
Abate by
Mar 3, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and defective components were not removed from service:  (a) Front of the Pennsylvania State Police Headquarters Building - An employee, working from a JLG aerial lift to install horizontal supports for the curtain wall between the second and third story, used a FallTech self-retracting lifeline, model 7276WR, for tying off to the aerial lift.  The labeling and markings on the FallTech self-retracting lifeline, model 7276WR, had become illegible due to wear, and this personal fall arrest component did not get removed from service, on or about November 21, 2019.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View S.E.K. Construction, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344466040.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.