Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NAVAL AIR WEAPONS STATION CHINA LAKE POLICE DEPARTMENT

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NAVAL AIR WEAPONS STATION CHINA LAKE POLICE DEPARTMENT in 800 EAST INYOKERN ROAD, RIDGECREST, CA 93555 (NAICS 922120). OSHA activity number 344482260.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Naval AIR Weapons Station China Lake Police Department — free Get an email when a new federal OSHA severe-injury report for Naval AIR Weapons Station China Lake Police Department is published. One employer, no account, unsubscribe in one click.
Site address
800 EAST INYOKERN ROAD
City
RIDGECREST
State
CA
ZIP
93555
Mailing
1 ADMINISTRATION CIRCLE, MAILSTOP 1003 BUILDING 1, ROOM 1050, RIDGECREST, CA 93555
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922120
Employees
75
Ownership type
D

7 citations on file for this inspection.

1910.101 B

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 31, 2020
Abate by
Mar 19, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tank cars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  (a) Lauritsen Entry Control Point Sentry Post on the vehicle entry side: The employer did not ensure that the storage of two propane cylinders was adequate.  The cylinders were located on the employee pathway and near vehicle entry access point at the guard post and the cylinders were not secured while they were stored. Employees were exposed to fire, burns, inhalation and explosion hazard(s).   (b) Propulsion Lab Entry Control Point Post 6 on the vehicle entry side: The employer did not ensure that the storage of one propane cylinders was adequate.  The cylinder was located by an employee pathway and near vehicle entry access point at the guard post and the cylinders were not secured while they were stored.  Employees were exposed to fire, burns, inhalation and explosion hazard(s).
Recent events (1)
  • — Z (S) $0

1910.110 B20 IV A

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 31, 2020
Abate by
Mar 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.110(b)(20)(iv)(a): All domestic and commercial appliance(s) were not installed in accordance with the requirements of NFPA 54-1969, Standard for the Installation of Gas Appliances and Gas Piping, which is incorporated by reference as specified in Section 1910.6  (a) Lauritsen Entry Control Point Sentry Post on the vehicle entry side: The employer did not ensure portable heaters were located at least 6 feet from any LP-Gas container(s). Employees were exposed to the risk of fire, burns, inhalation and explosion hazards.  (b) Propulsion Lab Entry Control Point Post 6 on the vehicle entry side: The employer did not ensure portable heaters were located at least 6 feet from any LP-Gas container(s). Employees were exposed to the risk of fire, burns, inhalation and explosion hazards.
Recent events (1)
  • — Z (S) $0

1910.141 C01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 31, 2020
Abate by
Mar 19, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.141(c)(1)(i): Toilet facilities were not provided in accordance with TABLE J-1 of this Section:  Sentry Post 6, Propulsion Lab Entry Control Point: The employer did not provide the correct number of toilet facilities for male and female use while employees were assigned to these guard posts.  Building 11020 which housed the original toilet facility(s) were unsafe for entry due to structural damage. Employees were exposed to adverse health effects.
Recent events (1)
  • — Z (S) $0

1910.141 D02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 31, 2020
Abate by
Mar 19, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water:  Lauritsen Entry Control Point Sentry Post: The employer did not provide hand washing facilities which also required hand soap or similar cleaning agents, and hand towels for the employees at/near the permanently stationed porta potty(s) posted at the guard/sentry station(s). Employees were exposed to adverse health effects.  Propulsion Lab Entry Control Point Post 6 on the vehicle entry side: The employer did not provide hand washing facilities which also required hand soap or similar cleaning agents, and hand towels for the employees at/near the permanently stationed porta potty(s) posted at the guard/sentry station(s). Employees were exposed to adverse health effects.  IN THE ALTERNATIVE  29 CFR 1910.1030(d)(2)(iii): The employer did not provide hand washing facilities which were readily accessible to employees:  Lauritsen Entry Control Point Sentry Post: The employer did not provide hand washing facilities which also required hand soap or similar cleaning agents, and hand towels for the employees due to occupational duties which had the increased potential of exposure to blood borne pathogens. Employees were at risk of adverse health effects.  Propulsion Lab Entry Control Point Post 6 on the vehicle entry side: The employer did not provide hand washing facilities which also required hand soap or similar cleaning agents, and hand towels for the employees due to occupational duties which had the increased potential of exposure to blood borne pathogens. Employees were at risk of adverse health effects.
Recent events (1)
  • — Z (S) $0

1910.145 C01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 31, 2020
Abate by
Mar 19, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.145(c)(1)(ii): All employees were not instructed that danger signs indicate immediate danger and that special precautions are necessary.  Sentry Post 6, Propulsion Lab Entry Control Point: The employer did not ensure employees were instructed not to enter  building 11020 following the red danger unsafe placard posted on the window.  Building 11020 was determined to be unsafe due to structural damage. Employees were exposed to the risk of lacerations, contusions, hospitalization and/or death.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 2 instances 2 exposed
Issued
Jan 31, 2020
Abate by
Mar 19, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  (a) Women's Locker room: A refrigerator was plugged into a relocatable power tap. Employees were exposed to fire and/or electrical shock hazards from using electrical equipment improperly.  (b) Lauritsen Sentry Gate: A refrigerator was plugged into a relocatable power tap. Employees were exposed to fire and/or electrical shock hazards from using electrical equipment improperly.
Recent events (1)
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 31, 2020
Abate by
Mar 19, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  Building Electrical Panel Closet: Employer permitted materials to be directly stored in front of the electrical panel.  This condition prevented access and  immediate shutdown of a circuit to the panel, particularly in the event of an emergency.  This condition exposed employees to an electrical and/or fire hazard.
Recent events (1)
  • — Z (S) $0

View Naval AIR Weapons Station China Lake Police Department's full OSHA safety record →