JAMAICA, NY —
OSHA Inspection: MA HOME IMPROVEMENT INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MA HOME IMPROVEMENT INC. in 172-58 GRAND CENTRAL PARKWAY, JAMAICA, NY 11432 (NAICS 238190). OSHA activity number 344488598.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MA HOME IMPROVEMENT INC.
- Site address
- 172-58 GRAND CENTRAL PARKWAY
- City
- JAMAICA
- State
- NY
- ZIP
- 11432
- Mailing
- 172-16 GRAND CENTRAL PKWY, JAMAICA, NY 11432
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238190
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Dec 13, 2019
- Abate by
- Dec 19, 2019
- Penalty
- Initial $2,500 · Current $2,500
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as follows: (a) At the worksite - The first and second levels of a tubular welded scaffold were not fully planked; on or about 12/04/19. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Recent events (1)
- — Z (S) $2500
1926.454 C03
- Issued
- Dec 13, 2019
- Abate by
- Jan 10, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(c)(3): The employer did not retrain each employee when inadequacies in the employee's work involving scaffolds indicates that the employee has not retained the requisite proficiency: (a) At the worksite - The tubular welded scaffold was not fully planked, did not have guardrails and the employees were using the frame of the scaffold to access the working levels; on or about 12/04/19. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Recent events (1)
- — Z (S) $0
1926.451 E01
- Issued
- Dec 13, 2019
- Abate by
- Dec 19, 2019
- Penalty
- Initial $5,001 · Current $5,001
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: (a) At the worksite - Employees used the scaffold frame to access the working levels. No ladder was provided; on or about 12/04/19. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19 MA Home Improvement Inc. WAS PREVIOUSLY CITED FOR A SERIOUS VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, 29 CFR 1926.451(e)(1), WHICH WAS CONTAINED IN THE OSHA INSPECTION NUMBER 1052571, CITATION 1, ITEM 3, ISSUED ON 07/16/15. THE CITATION BECAME FINAL ORDER ON 08/17/15.
Recent events (1)
- — Z (R) $5001
1926.451 G01 VII
- Issued
- Dec 13, 2019
- Abate by
- Dec 19, 2019
- Penalty
- Initial $6,252 · Current $6,252
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: (a) On the second level of the scaffold - At approximately 13 feet above the ground, no guardrails were installed; on or about 12/04/19. (b) On the third level of the scaffold - At approximately 17 above the ground, top rails were not installed on the open sides; on or about 12/04/19. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19 MA Home Improvement Inc. WAS PREVIOUSLY CITED FOR A SERIOUS VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, 29 CFR 1926.451(g)(1)(vii), WHICH WAS CONTAINED IN THE OSHA INSPECTION NUMBER 1052571, CITATION 1, ITEM 4, ISSUED ON 07/16/15. THE CITATION BECAME FINAL ORDER ON 08/17/15.
Recent events (1)
- — Z (R) $6252
More inspections at MA Home Improvement INC.
View MA Home Improvement INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238190)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344488598.