OSHA Inspection: ACE HARDWARE

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ACE HARDWARE in 1346 PENINSULA BLVD., HEWLETT, NY 11557 (NAICS 444130). OSHA activity number 344493101.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ACE Hardware — free Get an email when a new federal OSHA severe-injury report for ACE Hardware is published. One employer, no account, unsubscribe in one click.
Establishment
ACE HARDWARE
Site address
1346 PENINSULA BLVD.
City
HEWLETT
State
NY
ZIP
11557
Mailing
1346 PENINSULA BLVD., HEWLETT, NY 11557
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444130
Employees
12
Ownership type
A

5 citations on file for this inspection.

1910.36 D01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 12, 2020
Penalty
Initial $3,084 · Current $1,853 Reduced
29 CFR 1910.36(d)(1): The employer did not provide employees with an open exit route door from the inside at all times without keys, tools, or special knowledge.    At the worksite; back, exit door was locked, on or about 12/6/2019.    Note:     Because abatement of this violation is already documented in the case the employer need not submit certification or documentation of abatement of this violation normally required by 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1853
  • — Z (S) $3084

1910.37 A03

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 12, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit routes was not free and unobstructed. Materials were placed, either permanently or temporarily, within the exit route.   At the worksite; back, exit door was blocked with a safety fence, on or about 12/6/2019.  Note:     Because abatement of this violation is already documented in the case the employer need not submit certification or documentation of abatement of this violation normally required by 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B06

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 12, 2020
Abate by
Apr 7, 2020
Penalty
Initial $3,084 · Current $1,853 Reduced
29 CFR 1910.37(b)(6):  The employer did not provide each exit sign illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. Self-luminous or electroluminescent signs that have a minimum luminance surface value of at least .06 footlamberts (0.21 cd/m2);    a) At the worksite; Front door, the exit sign was not adequately lighted; on or about 12/6/19.    Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1853
  • — Z (S) $3084

1910.157 G01

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 12, 2020
Abate by
Apr 7, 2020
Penalty
Initial $2,313 · Current $1,389 Reduced
29 CFR 1910.157(g)(1):  An educational program was not provided for all employee to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:    (a) At the work site, Where fire extinguishers were provided for employee's use, the employer did not provide employees with an educational program to familiarize employees in the general principles of fire extinguisher use, on or about 12/6/19.    * ABATEMENT NOTE * By this date the employer must either correct the alleged violation  or implement a Fire Safety Policy; as outlined in 29 CFR 1910.38(a) and (b) which includes the  evacuation requirements of 29 CFR 1910.157(b).    Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1389
  • — Z (S) $2313

1910.304 F01 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 12, 2020
Penalty
Initial $3,084 · Current $1,853 Reduced
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:    a) Storage area: Electrical panel boxes that power lights, were blocked by boxes and signs; on or about 12/6/19.      NOTE: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of this violation as normally required by 29 CFR 1903.19.