DALLAS, TX —
OSHA Inspection: STANDARD MEAT COMPANY, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of STANDARD MEAT COMPANY, LLC in 5105 INVESTMENT DR., DALLAS, TX 75236 (NAICS 311612). OSHA activity number 344506225.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STANDARD MEAT COMPANY, LLC
- Site address
- 5105 INVESTMENT DR.
- City
- DALLAS
- State
- TX
- ZIP
- 75236
- Mailing
- 5105 INVESTMENT DR., DALLAS, TX 75236
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311612
- Employees
- 365
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Apr 14, 2020
- Abate by
- Apr 24, 2020
- Penalty
- Initial $13,494 · Current $8,096 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about December 3, 2019, and at times prior thereto; the employer did not develop, document and utilize procedures for the control of potentially hazardous energy when employees were performed any servicing, and maintenance on Lift Pallet Conveyor, exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $8096.4
- — Z (S) $13494
1910.147 C05 II D
- Issued
- Apr 14, 2020
- Abate by
- Apr 24, 2020
- Penalty
- Initial $9,639 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s): a) The employer did not ensure lockout devices indicate the identity of the employee applying the devices. On or about December 10, 2019, in the Pack Off department, lockout device and tagout device applied to main disconnect to the Lift Pallett conveyor system did not indicate the identity of the employee applying the devices.
Recent events (2)
- — I (S) $0
- — Z (S) $9639
1910.147 C06 II
- Issued
- Apr 14, 2020
- Abate by
- Apr 24, 2020
- Penalty
- Initial $13,494 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection: a) On or about December 10, 2019, and at times prior thereto, the employer did not conduct a periodic inspection of the energy control procedure at least annually.
Recent events (2)
- — I (O) $0
- — Z (S) $13494
More inspections at Standard Meat Company, LLC
View Standard Meat Company, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311612)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344506225.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.