FORT GREELY, AK —
OSHA Inspection: ARMY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARMY in DIRECTORATE OF FAMILY, MORALE, WELFARE & RECREATION, FORT GREELY, AK 99731 (NAICS 713940). OSHA activity number 344512140.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARMY
- Site address
- DIRECTORATE OF FAMILY, MORALE, WELFARE & RECREATION
- City
- FORT GREELY
- State
- AK
- ZIP
- 99731
- Mailing
- BOX 31269, FORT GREELY, AK 99731
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713940
- Employees
- 20
- Ownership type
- D
Citations
7 citations on file for this inspection.
1910.28 B01 I
- Issued
- Jan 14, 2020
- Abate by
- Feb 3, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: Outdoor Recreation, Elevated Storage, Breakroom: On or about December 12, 2019 and at times prior thereto, employees accessed mezzanine area. This condition exposed employees to a fall hazard of 8.9 feet.
Recent events (1)
- — Z (S) $0
1910.132 D02
- Issued
- Jan 14, 2020
- Abate by
- Feb 3, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment: (a) CAC, Fahrenheit Bar & Grill: On or about December 11, 2019 and at times prior thereto, where employees perform workplace tasks requiring the use of personal protective equipment, including but not limited to the use of corrosive cleaning products, the employer had not performed a workplace hazard assessment. This condition exposed employees to eye and skin hazards. (b) Outdoor Recreation: On or about December 12, 2019 and at times prior thereto, where employees perform workplace tasks requiring the use of personal protective equipment, including but not limited to the use of a Class III/IV Laser Engraver, the employer had not performed a workplace hazard assessment. This condition exposed employees to eye and skin hazards.
Recent events (1)
- — Z (S) $0
1910.242 B
- Issued
- Jan 14, 2020
- Abate by
- Feb 3, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: Outdoor Recreation: On or about December 12, 2019 and at times prior thereto, a compressed air tool used for cleaning operated at 90 p.s.i.g. without reduction. This condition exposed employees to air embolism hazards from contact with the air tool nozzle.
Recent events (1)
- — Z (S) $0
1910.334 A01
- Issued
- Jan 14, 2020
- Abate by
- Feb 3, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(1): Portable electric equipment was not handled in a manner which would not cause damage: (a) Outdoor Recreation, Customer Service Desk: On or about December 12, 2019 and at times prior thereto, an extension cord used to energize computer equipment was kinked and routed under a cushioned map. This condition exposed employees to fire and smoke-inhalation hazards. (b) Outdoor Recreation, Customer Service Desk: On or about December 12, 2019 and at times prior thereto, an extension cord used to energize computer equipment was kinked and routed under a cushioned map. This condition exposed employees to fire and smoke-inhalation hazards. (c) CAC, Bowling Center, Maintenance Area: On or about December 11, 2019 and at times prior thereto, an extension cord used to energize computer equipment was kinked and routed under a cushioned map. This condition exposed employees to fire and smoke-inhalation hazards.
Recent events (1)
- — Z (S) $0
1910.159 C10
- Issued
- Jan 14, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.159(c)(10): The minimum vertical clearance of 18 inches between automatic sprinkler systems sprinklers and the material below was not maintained: CAC, Fahrenheit Bar & Grill, Dishwash Area: On or about December 11, 2019 and at times prior thereto, a mobile shelf unit was placed directly under a sprinkler which minimized the vertical clearance to 13 inches. This condition limited the uniform coverage of the sprinkler.
Recent events (1)
- — Z (O) $0
1910.178 L04 II D
- Issued
- Jan 14, 2020
- Abate by
- Feb 3, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(ii)(D): The operator had not been provided refresher when assigned to drive a different type of truck: Outdoor Recreation: On or about December 12, 2019 and at times prior thereto, an employee anticipated to operate a TerexLift TX 51-19M powered industrial truck had not been provided refresher training. This condition limited the employee's knowledge of the equipment's specific capabilities.
Recent events (1)
- — Z (O) $0
1910.1200 F06 II
- Issued
- Jan 14, 2020
- Abate by
- Feb 3, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: CAC, Fahrenheit Bar & Grill, Dishwash Area: On or about December 11, 2019 and at times prior thereto, unlabled spray bottles with a mixture of soap and water were present and available for use. This condition exposed employees to an eye irritant.
Recent events (1)
- — Z (O) $0
More inspections at Army
View Army's full OSHA safety record →
More inspections in this industry (NAICS 713940)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344512140.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.