MINERVA, OH —
OSHA Inspection: ENERGY TRANSFER
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of ENERGY TRANSFER in 9312 ARROW ROAD NW, MINERVA, OH 44657 (NAICS 333513). OSHA activity number 344518477.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ENERGY TRANSFER
- Site address
- 9312 ARROW ROAD NW
- City
- MINERVA
- State
- OH
- ZIP
- 44657
- Mailing
- 9312 ARROW ROAD NW, MINERVA, OH 44657
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333513
- Employees
- 85
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II D
- Issued
- Apr 6, 2020
- Penalty
- Initial $6,940 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control" a) On or about December 12, 2019, the employer's energy control procedures to include but not limited to the M096 Pacific Press Brake Model K2258, SN: A1393, located in the Tube Forming department, did not contain a verification step. b) On or about December 12, 2019, the employer's energy control procedures to include but not limited to the M151 Pacific Press Brake Model J90-1, SN: A1006, located in the Tube Forming department, did not contain a verification step.
Recent events (2)
- — I (S) $0
- — Z (S) $6940
1910.147 C06 I
- Issued
- Apr 6, 2020
- Abate by
- Apr 30, 2020
- Penalty
- Initial $0 · Current $5,000
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about December 12, 2019, the employer did not ensure periodic inspections of energy control procedures were being performed at least annually to ensure the requirements of the standard were being followed. The employer did not ensure an inspection was conducted of each energy control procedure to correct any inadequacies or deviations in the procedure [per 1910.147(c)(6)(i)(B) requirements], and/or annual periodic inspections included a review of each authorized employee and their responsibilities under the energy control procedure [(c)(6)(i)(C)].
Recent events (2)
- — I (S) $5000
- — Z (S) $0
1910.212 A01
- Issued
- Apr 6, 2020
- Penalty
- Initial $12,145 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about December 12, 2019, the employer failed to ensure that the M096 Pacific Press Brake Model K2258, SN: A1393, located in the Tube Forming department, had machine guarding methods in place to protect employees from caught in/crushing hazards of the hydraulic press. b) On or about December 12, 2019, the employer failed to ensure that the M151 Pacific Press Brake Model J90-1, SN: A1006, located in the Tube Forming department, had machine guarding methods in place to protect employees from caught in/crushing hazards of the hydraulic press.
Recent events (2)
- — I (S) $0
- — Z (S) $12145
More inspections at Energy Transfer
View Energy Transfer's full OSHA safety record →
More inspections in this industry (NAICS 333513)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344518477.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.