Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ENERGY TRANSFER

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ENERGY TRANSFER in 9312 ARROW ROAD NW, MINERVA, OH 44657 (NAICS 333513). OSHA activity number 344518477.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Energy Transfer — free Get an email when a new federal OSHA severe-injury report for Energy Transfer is published. One employer, no account, unsubscribe in one click.
Establishment
ENERGY TRANSFER
Site address
9312 ARROW ROAD NW
City
MINERVA
State
OH
ZIP
44657
Mailing
9312 ARROW ROAD NW, MINERVA, OH 44657
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333513
Employees
85
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II D

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Apr 6, 2020
Penalty
Initial $6,940 · Current $0 Reduced
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control"  a) On or about December 12, 2019, the employer's energy control procedures to include but not limited to the M096 Pacific Press Brake Model K2258, SN: A1393, located in the Tube Forming department, did not contain a verification step.   b) On or about December 12, 2019, the employer's energy control procedures to include but not limited to the M151 Pacific Press Brake Model J90-1, SN: A1006, located in the Tube Forming department, did not contain a verification step.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6940

1910.147 C06 I

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 6, 2020
Abate by
Apr 30, 2020
Penalty
Initial $0 · Current $5,000
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    On or about December 12, 2019, the employer did not ensure periodic inspections of energy control procedures were being performed at least annually to ensure the requirements of the standard were being followed.  The employer did not ensure an inspection was conducted of each energy control procedure to correct any inadequacies or deviations in the procedure [per 1910.147(c)(6)(i)(B) requirements], and/or annual periodic inspections included a review of each authorized employee and their responsibilities under the energy control procedure [(c)(6)(i)(C)].
Recent events (2)
  • — I (S) $5000
  • — Z (S) $0

1910.212 A01

Deleted Serious Gravity 10 2 instances 3 exposed
Issued
Apr 6, 2020
Penalty
Initial $12,145 · Current $0 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) On or about December 12, 2019, the employer failed to ensure that the M096 Pacific Press Brake Model K2258,  SN: A1393, located in the Tube Forming department, had machine guarding methods in place to protect employees from caught in/crushing hazards of the hydraulic press.  b) On or about December 12, 2019, the employer failed to ensure that the M151 Pacific Press Brake Model J90-1,   SN: A1006, located in the Tube Forming department, had machine guarding methods in place to protect employees from caught in/crushing hazards of the hydraulic press.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12145

View Energy Transfer's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344518477.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.