WEST UNITY, OH —
OSHA Inspection: BDJ/TECHMATION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BDJ/TECHMATION, INC. in 516 NORTH PARKWAY, WEST UNITY, OH 43570 (NAICS 332812). OSHA activity number 344521059.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BDJ/TECHMATION, INC.
- Site address
- 516 NORTH PARKWAY
- City
- WEST UNITY
- State
- OH
- ZIP
- 43570
- Mailing
- P.O. BOX 859, WEST UNITY, OH 43570
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 35
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.107 C06
- Issued
- Apr 15, 2020
- Abate by
- Apr 28, 2020
- Penalty
- Initial $8,096 · Current $4,048 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: a) BDJ/Techmation, Inc. located at 516 North Parkway in West Unity, Ohio; On or about December 19, 2019 the employer did not ensure electrical wiring, motors, and other equipment outside of but within twenty feet of the spray area were designed for class 1 division 2 hazardous locations. Employees were exposed to fire hazards in that an electrical outlet located within approximately seven feet and four inches of the spray booth.
Recent events (2)
- — I (S) $4048
- — Z (S) $8096
1910.107 G02
- Issued
- Apr 15, 2020
- Abate by
- Jun 30, 2020
- Penalty
- Initial $8,096 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: a) BDJ/Techmation, Inc. located at 516 North Parkway in West Unity, Ohio; On or about December 19, 2019 the employer did not ensure spraying areas were kept free from accumulations of deposits of combustible residues. Employees were exposed to hazards associated with fires in that accumulations of paint such as, but not limited to, Black CI Primer, were observed on the floor, walls, and equipment near Line 10 K010 Paint Booth.
Recent events (2)
- — I (S) $0
- — Z (S) $8096
1910.107 B05 I
- Issued
- Apr 15, 2020
- Abate by
- Jun 30, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(5)(i): The average air speed over the open face of the paint spray booth was less than 100 linear feet per minute. a) BDJ/Techmation, Inc. located at 516 North Parkway in West Unity, Ohio; On or about February 25, 2020 the employer did not ensure the spraying operation maintained an average air velocity over the open face of the booth of not less than 100 linear feet per minute. Employees were exposed to hazards associated with fires in that accumulations of paint such as, but not limited to, Black CI Primer, were observed on the floor, walls, and equipment outside of Line 10 K010 Paint Booth.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Apr 15, 2020
- Abate by
- Jun 15, 2020
- Penalty
- Initial $9,446 · Current $4,723 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) BDJ/Techmation, Inc. located at 516 North Parkway in West Unity, Ohio; On or about December 19, 2019 the employer did not assure that the point of operation on the Cam Tech Router Master was guarded. Employees operating the router table were exposed to laceration and amputation hazards in that the point of operation was not guarded.
Recent events (2)
- — I (S) $4723
- — Z (S) $9446
More inspections at Bdj/Techmation, INC.
View Bdj/Techmation, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344521059.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.