PUEBLO, CO —
OSHA Inspection: DRURY BROTHERS ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DRURY BROTHERS ROOFING, INC. in 4137 N. ELIZABETH ST., PUEBLO, CO 81008 (NAICS 238160). OSHA activity number 344521133.
Where did this inspection happen?
- Establishment
- DRURY BROTHERS ROOFING, INC.
- Site address
- 4137 N. ELIZABETH ST.
- City
- PUEBLO
- State
- CO
- ZIP
- 81008
- Mailing
- 2201 N. I-25, PUEBLO, CO 81005
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $3789.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) On or about December 4, 2019, employees were exposed to head injuries because they were not wearing protective helmets when they were working under other employees performing roofing activities above who were throwing down debris to the employees on the ground so that it could be placed in trash receptacles.
Recent events (2)
- — I (S) $500
- — Z (S) $3789
1926.501 B10
- Issued
- Abate by
- Penalty
- Initial $29172.00 · Current $18000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, is not being protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: (a) Drury Brothers Roofing, Inc., is failing to ensure that its employees are protected from fall hazards during roofing work. This was most recently observed on December 4, 2019, when employees of Drury Brothers Roofing Inc. were reroofing a commercial building without fall protection. The eaves of the roof were 10 feet above the ground with a 4:12 pitch roof. Drury Brothers Roofing Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.501(b)(11), which was contained in OSHA inspection number 1405617, citation number 1, item number 1, and was affirmed as a final order on August 22, 2019, with respect to a workplace located at 202 Manitou Ave., Manitou Springs, CO. Drury Brothers Roofing Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.501(b)(11), which was contained in OSHA inspection number 1251645, citation number 1, item number 1, and was affirmed as a final order on August 30, 2017, with respect to a workplace located at 602 Main Street in Ordway, Colorado. Drury Brothers Roofing Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1202462, citation number 1, item number 1, and was affirmed as a final order on February 14, 2017, with respect to a workplace located at 4346 Yellow Dock Point in Colorado Springs, Colorado.
Recent events (2)
- — I (R) $18000
- — Z (R) $29172
More inspections at DRURY BROTHERS ROOFING, INC.
MANITOU SPRINGS, CO—2019-05-31 00:00:00
DRURY BROTHERS ROOFING INC.
ORDWAY, CO—2017-07-21 00:00:00
DRURY BROTHERS ROOFING, INC.
COLORADO SPRINGS, CO—2017-01-12 00:00:00
DRURY BROTHERS ROOFING, INC.
TUCSON, AZ—2015-03-10 00:00:00
DRURY BROTHERS ROOFING, INC.
COLORADO SPRINGS, CO—2013-05-23 00:00:00
DRURY BROTHERS ROOFING, INC.
View DRURY BROTHERS ROOFING, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344521133.