Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J.D. MILLER & SONS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J.D. MILLER & SONS, LLC in N 7102 STATE RD 40, ELK MOUND, WI 54739 (NAICS 423510). OSHA activity number 344522768.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J.D. Miller & Sons, LLC — free Get an email when a new federal OSHA severe-injury report for J.D. Miller & Sons, LLC is published. One employer, no account, unsubscribe in one click.
Site address
N 7102 STATE RD 40
City
ELK MOUND
State
WI
ZIP
54739
Mailing
N 7102 STATE RD 40, ELK MOUND, WI 54739
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423510
Employees
7
Ownership type
A

6 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 24, 2020
Abate by
May 12, 2020
Penalty
Initial $4,241 · Current $1,272 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a) Throughout the facility; An energy control program (Lockout-Tagout) was not implemented prior to employees performing lockout covered actives of setup, servicing, and maintenance activities on equipment, such as a Chicago shear, Accura bandsaw, and Piranha ironworker.
Recent events (2)
  • — I (S) $1272.3
  • — Z (S) $4241

1910.212 A01

Serious Gravity 5 2 instances 4 exposed
Issued
Apr 24, 2020
Abate by
May 12, 2020
Penalty
Initial $4,241 · Current $1,272 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) North end of shop; Rotating parts and flying chips were not guarded on a Cal-Hawk brand drill press.    (b) Shop area; Nip-points beneath material hold-downs were not guarded on a 10-foot Pearson brand hydraulic shear.
Recent events (2)
  • — I (S) $1272.3
  • — Z (S) $4241

1910.215 B09

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 24, 2020
Penalty
Initial $2,545 · Current $764 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    (a) North end of shop; The gap between the each upper guard and stone grinding wheel on a pedestal mounted bench grinder was greater than one fourth of an inch.
Recent events (2)
  • — I (S) $763.5
  • — Z (S) $2545

1910.253 B02 II

Serious Gravity 1 1 instance 7 exposed
Issued
Apr 24, 2020
Penalty
Initial $2,545 · Current $764 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:    (a) North end of shop; Acetylene gas cylinders stored next to an exit way door were not secured and/or protected from physical damage.
Recent events (2)
  • — I (S) $763.5
  • — Z (S) $2545

1910.305 B02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 24, 2020
Penalty
Initial $2,545 · Current $764 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    (a) Shop area; Energized conductor wires were exposed on a Chicago brand, powered apron brake because a cover plate was not in place on an electrical junction box located directly beneath the operational controls of the apron brake.
Recent events (2)
  • — I (S) $763.5
  • — Z (S) $2545

1910.212 A03 II

Repeat Gravity 5 1 instance 4 exposed
Issued
Apr 24, 2020
Abate by
May 12, 2020
Penalty
Initial $8,482 · Current $2,165 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     (a) Shop area; Points of operation were not guarded on an ironworker machine.    The J.D. Miller and Sons, LLC dba Steel Towne was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(3)(ii), which was contained in OSHA inspection number 1016905, citation number 1, item number 1 and was affirmed as a final order on July 15, 2015, with respect to a workplace located at N8166 Highway 65, River Falls, WI 54022.