MILWAUKEE, WI —
OSHA Inspection: ADVANCE DIE CAST
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ADVANCE DIE CAST in 3760 N HOLTON ST, MILWAUKEE, WI 53212 (NAICS 331521). OSHA activity number 344534433.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCE DIE CAST
- Site address
- 3760 N HOLTON ST
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53212
- Mailing
- 3760 N HOLTON ST, MILWAUKEE, WI 53212
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331521
- Employees
- 86
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.219 C04 I
- Issued
- Jan 23, 2020
- Abate by
- Mar 11, 2020
- Penalty
- Initial $5,783 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves. a. On or about January 8, 2020, a rotating projecting shaft end on the Vibe machine was not guarded which exposed employees to caught in hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $5783
1910.178 A03
- Issued
- Jan 23, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(3): Approved trucks shall bear a label or some other identifying mark indicating approval by the testing laboratory. See paragraph (a)(7) of this section and paragraph 405 of "American National Standard for Powered Industrial Trucks, Part II, ANSI B56.1-1969", which is incorporated by reference in paragraph (a)(2) of this section and which provides that if the powered industrial truck is accepted by a nationally recognized testing laboratory it should be so marked. a. On or about January 8, 2019, the powered industrial truck Clark model GCS30WC identified by Green Bay Packer logo and the #8 did not have a legible label.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Advance DIE Cast
View Advance DIE Cast's full OSHA safety record →
More inspections in this industry (NAICS 331521)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344534433.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.