Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ICON LEGACY CUSTOM MODULAR HOMES LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ICON LEGACY CUSTOM MODULAR HOMES LLC in 246 SAND HILL ROAD, SELINSGROVE, PA 17870 (NAICS 321992). OSHA activity number 344560040.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Icon Legacy Custom Modular Homes LLC — free Get an email when a new federal OSHA severe-injury report for Icon Legacy Custom Modular Homes LLC is published. One employer, no account, unsubscribe in one click.
Site address
246 SAND HILL ROAD
City
SELINSGROVE
State
PA
ZIP
17870
Mailing
246 SAND HILL ROAD, SELINSGROVE, PA 17870
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321992
Employees
125
Ownership type
A

8 citations on file for this inspection.

1910.28 B03 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 2, 2020
Abate by
Aug 1, 2020
Penalty
Initial $9,543 · Current $6,200 Reduced
29 CFR 1910.28(b)(3)(i): The employer did not ensure that each employee was protected from falling through any hole (including skylights) that were 4 feet (1.2 m) or more above a lower level:     a) Roofing Department: The employer did not ensure that each employee was protected from falling through holes (gaps) created by the spaces between the elevated platforms and the home units, as observed on or about January 14, 2020.    Abatement Certification Required.
Recent events (2)
  • — I (S) $6200
  • — Z (S) $9543

1910.29 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 2, 2020
Abate by
Aug 1, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.29(b)(1): The top edge height of top rails, or equivalent guardrail system members, were not 42 inches, plus or minus 3 inches, above the walking-working surface:    a) Roofing Department: The height of the top rail (chain guardrail) positioned on the right side elevated platform was at a height of 31 inches, as observed on or about January 14, 2020.    Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.29 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.29(b)(2): The employer did not ensure that midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent intermediate members are installed between the walking-working surface and the top edge of the guardrail system as follows when there is not a wall or parapet that is at least 21 inches (53 cm) high:  a) Roofing Department: The mid rails for the roofing mezzanine storage area were damaged and/or missing, as observed on or about January 14, 2020.  Abatement Observed During Inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 B03 II A

Other-than-serious 1 instance 1 exposed
Issued
Apr 2, 2020
Penalty
Initial $5,726 · Current $0 Reduced
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15, 20 and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel did not have ground-fault circuit-interrupter protection for personnel:    a) Station #7 (Yard): A flexible electrical cord used by employees in the yard was not equipped with ground-fault circuit interrupter protection, as observed on or about January 14, 2020.    Abatement Observed During Inspection.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5726

1910.305 B02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  a) Wall Building Department (Station #3): An electrical receptacle box was not equipped with an approved cover, as observed on or about January 14, 2020.  Abatement Observed During Inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.28 B01 I

Repeat Gravity 5 1 instance 4 exposed
Issued
Apr 2, 2020
Abate by
Aug 1, 2020
Penalty
Initial $19,085 · Current $15,800 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling:     a) Roofing Department (Station #5): Employees working on an elevated platform approximately 7 feet above the floor level were not protected from falling to the lower level, as observed on or about January 14, 2020.    b) Roofing Department (Station #5): Employees working on the roof level on home units approximately 11 feet above the floor level were not properly guarded from falling to the lower level, as observed on or about January 14, 2020.     The employer was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard which was contained in OSHA inspection number 1165414, citation number 1, item number 1 and was affirmed as a final order on November 3, 2016 with respect to a workplace located in Selinsgrove, PA.    Abatement Certification and Documentation Required.
Recent events (2)
  • — I (R) $15800
  • — Z (R) $19085

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Apr 2, 2020
Abate by
Aug 1, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) Maintenance: The employer did not conduct a periodic inspection of the energy control procedures at least annually for equipment including, but not limited to, woodworking equipment and baler, on or about January 21, 2020.    Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.184 E01

Other-than-serious 1 instance 1 exposed
Issued
Apr 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach:  a) Floor and Ceiling Departments: Alloy steel chain slings did not have permanently affixed durable identification tags stating size, grade, rated capacity and reach, as observed on or about January 14, 2020.  Abatement Observed During Inspection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Icon Legacy Custom Modular Homes LLC's full OSHA safety record →