SAIPAN, MP —
OSHA Inspection: IMPERIAL PACIFIC RESORT
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of IMPERIAL PACIFIC RESORT in CORNER OF BEACH RD. AND ORCHID ST. GARAPAN, SAIPAN, MP 96950 (NAICS 721120). OSHA activity number 344566443.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IMPERIAL PACIFIC RESORT
- Site address
- CORNER OF BEACH RD. AND ORCHID ST. GARAPAN
- City
- SAIPAN
- State
- MP
- ZIP
- 96950
- Mailing
- PMB 242 PPP BOX 10000, SAIPAN, MP 96950
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721120
- Employees
- 569
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 A01
- Issued
- Jun 18, 2020
- Penalty
- Initial $13,494 · Current $13,494
General-duty citation text
29 CFR 1926.451(a)(1): Each scaffold and scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it. On January 10, 2010 on the fourth floor south tower: A scaffold loaded with granite reinforced concrete (GRC) collapsed while three employees used the scaffold to transfer door beams up to the next level. Employees were exposed to fall hazards.
Recent events (1)
- — Z (S) $13494
1926.451 A03
- Issued
- Jun 18, 2020
- Penalty
- Initial $13,494 · Current $13,494
General-duty citation text
29 CFR 1926.451(a)(3): Each suspension rope, including connecting hardware, used on non-adjustable suspension scaffolds was not capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope On January 10, 2010 on the fourth floor south tower: Wire ropes used to suspend the scaffold broke while three employees used the scaffold to transfer equipment to the next level. Employees were exposed to fall hazards.
Recent events (1)
- — Z (S) $13494
1926.451 A06
- Issued
- Jun 18, 2020
- Penalty
- Initial $13,494 · Current $13,494
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person. On January 10, 2010 on the fourth floor south tower: The needle beam type scaffolding was not designed to hold the weight of the scaffolding, added materials and workers. A scaffold loaded with granite reinforced concrete (GRC) collapsed while three employees used the scaffold to transfer door beams up to the next level. Employees were exposed to fall hazards.
Recent events (1)
- — Z (S) $13494
1926.451 D12 VI
- Issued
- Jun 18, 2020
- Penalty
- Initial $9,639 · Current $9,639
General-duty citation text
29 CFR 1926.451(d)(12)(vi): When U-bolt clips are used, the U-bolt shall be placed over the dead end of the rope, and the saddle shall be placed over the live end of the rope. January 10, 2010 on the fourth floor south tower: The U section of U-bolt wire rope clips used as part of the system to support the scaffolding were not installed in contact with the dead end and the saddle on the live end of the rope. Employees were exposed to fall hazards.
Recent events (1)
- — Z (S) $9639
1926.451 F03
- Issued
- Jun 18, 2020
- Penalty
- Initial $13,494 · Current $13,494
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. On January 10, 2010 on the fourth floor south tower: The scaffolding in use to transfer materials was not inspected by a competent person before the start of work. Employees were exposed to fall hazards.
Recent events (1)
- — Z (S) $13494
1926.451 F04
- Issued
- Jun 18, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(4): Damaged or weakened parts of a scaffold were not immediately repaired or replaced, braced, or removed from service until repaired: On January 10, 2010 on the fourth floor south tower: Severely corroded cables used to suspend the scaffold that was in use were not replaced nor was the scaffold removed from service. Employees were exposed to fall hazards.
Recent events (1)
- — Z (S) $0
1904.40 A
- Issued
- Jun 18, 2020
- Penalty
- Initial $1,928 · Current $1,928
General-duty citation text
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours. The required OSHA 300 logs were not provided when verbally requested on January 17, 2020, and when requested via email on February 14 2020.
Recent events (1)
- — Z (O) $1928
More inspections at Imperial Pacific Resort
View Imperial Pacific Resort's full OSHA safety record →
More inspections in this industry (NAICS 721120)
More inspections in MP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344566443.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.