Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IMPERIAL PACIFIC RESORT

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of IMPERIAL PACIFIC RESORT in CORNER OF BEACH RD. AND ORCHID ST. GARAPAN, SAIPAN, MP 96950 (NAICS 721120). OSHA activity number 344566443.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Imperial Pacific Resort — free Get an email when a new federal OSHA severe-injury report for Imperial Pacific Resort is published. One employer, no account, unsubscribe in one click.
Site address
CORNER OF BEACH RD. AND ORCHID ST. GARAPAN
City
SAIPAN
State
MP
ZIP
96950
Mailing
PMB 242 PPP BOX 10000, SAIPAN, MP 96950
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721120
Employees
569
Ownership type
A

7 citations on file for this inspection.

1926.451 A01

Serious Gravity 10 3 instances 6 exposed
Issued
Jun 18, 2020
Penalty
Initial $13,494 · Current $13,494
29 CFR 1926.451(a)(1): Each scaffold and scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.  On January 10, 2010 on the fourth floor south tower: A scaffold loaded with granite reinforced concrete (GRC) collapsed while three employees used the scaffold to transfer door beams up to the next level. Employees were exposed to fall hazards.
Recent events (1)
  • — Z (S) $13494

1926.451 A03

Serious Gravity 10 3 instances 6 exposed
Issued
Jun 18, 2020
Penalty
Initial $13,494 · Current $13,494
29 CFR 1926.451(a)(3): Each suspension rope, including connecting hardware, used on non-adjustable suspension scaffolds was not capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope  On January 10, 2010 on the fourth floor south tower: Wire ropes used to suspend the scaffold broke while three employees used the scaffold to transfer equipment to the next level. Employees were exposed to fall hazards.
Recent events (1)
  • — Z (S) $13494

1926.451 A06

Serious Gravity 10 3 instances 6 exposed
Issued
Jun 18, 2020
Penalty
Initial $13,494 · Current $13,494
29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person.  On January 10, 2010 on the fourth floor south tower: The needle beam type scaffolding was not designed to hold the weight of the scaffolding, added materials and workers. A scaffold loaded with granite reinforced concrete (GRC) collapsed while three employees used the scaffold to transfer door beams up to the next level. Employees were exposed to fall hazards.
Recent events (1)
  • — Z (S) $13494

1926.451 D12 VI

Serious Gravity 5 4 instances 6 exposed
Issued
Jun 18, 2020
Penalty
Initial $9,639 · Current $9,639
29 CFR 1926.451(d)(12)(vi): When U-bolt clips are used, the U-bolt shall be placed over the dead end of the rope, and the saddle shall be placed over the live end of the rope.  January 10, 2010 on the fourth floor south tower: The U section of U-bolt wire rope clips used as part of the system to support the scaffolding were not installed in contact with the dead end and the saddle on the live end of the rope. Employees were exposed to fall hazards.
Recent events (1)
  • — Z (S) $9639

1926.451 F03

Serious Gravity 10 3 instances 6 exposed
Issued
Jun 18, 2020
Penalty
Initial $13,494 · Current $13,494
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.  On January 10, 2010 on the fourth floor south tower: The scaffolding in use to transfer materials was not inspected by a competent person before the start of work. Employees were exposed to fall hazards.
Recent events (1)
  • — Z (S) $13494

1926.451 F04

Serious Gravity 10 4 instances 6 exposed
Issued
Jun 18, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(4): Damaged or weakened parts of a scaffold were not immediately repaired or replaced, braced, or removed from service until repaired:   On January 10, 2010 on the fourth floor south tower: Severely corroded cables used to suspend the scaffold that was in use were not replaced nor was the scaffold removed from service.  Employees were exposed to fall hazards.
Recent events (1)
  • — Z (S) $0

1904.40 A

Other-than-serious 1 instance 300 exposed
Issued
Jun 18, 2020
Penalty
Initial $1,928 · Current $1,928
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours.  The required OSHA 300 logs were not provided when verbally requested on January 17, 2020, and when requested via email on February 14 2020.
Recent events (1)
  • — Z (O) $1928

View Imperial Pacific Resort's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344566443.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.