YANKTON, SD ·
OSHA Inspection: HYDRO EXTRUSION USA, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HYDRO EXTRUSION USA, LLC in 2500 ALUMAX ROAD, YANKTON, SD 57078 (NAICS 423510). OSHA activity number 344580105.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HYDRO EXTRUSION USA, LLC
- Site address
- 2500 ALUMAX ROAD
- City
- YANKTON
- State
- SD
- ZIP
- 57078
- Mailing
- 2500 ALUMAX ROAD, YANKTON, SD 57078
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423510
- Employees
- 404
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Jun 18, 2020
- Abate by
- Jul 15, 2020
- Penalty
- Initial $9,543 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (b)Hydro Extrusion USA, LLC at 2500 Alumax Road, Yankton, SD 57078: On or about and at times prior to January 23, 2020, the employer did not ensure employees were protected from amputation hazards associated with a 36-inch DoALL Horizontal Bandsaw, Model #C-916M, located in the maintenance shop. The employer did not ensure that the unused portion of the saw blade was protected or otherwise guarded. The bandsaw had 16 inches of unused, exposed blade which was not guarded at the point of operation. This condition exposed employees to laceration and amputation hazards.
Recent events (2)
- · I (S) $6000
- · Z (S) $9543
1910.212 A03 II
- Issued
- Jun 18, 2020
- Abate by
- Jul 15, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point of operation of machinery were not guarded or guards were not designed and constructed to prevent employees from having any part of their body in the danger zone during operating cycles: (a)Hydro Extrusion USA, LLC at 2500 Alumax Road, Yankton, SD 57078: On or about and at times prior to January 23, 2020, the employer did not ensure employees were protected from the point of operation while operating the horizontal hydraulic press located in the maintenance shop without an effective machine guard. This condition exposed employees to an amputation hazard. Abatement Note: Examples of acceptable machine guards may include barrier guards, two hand tripping devices, and electronic light curtains. Additionally, use of special hand tools to keep hands away from the point of operation is acceptable regarding 29 CFR 1910.212(a)(3(iii). Abatement Note: Safeguarding by maintaining a "safe distance" is acceptable, during normal production operation, if the operating employee does not approach closer than necessary and in no case, closer than 4 inches (10.16 centimeters), to the point of operation as required under CPL 2-1.25, Guidelines for Point of Operation Guarding of Power Press Brakes paragraph and ANSI B11.3-1982, Safety Requirements for Power Press Brakes. One feasible and acceptable abatement method to correct this hazard is to ensure that each employee who works on the power press brakes receives documented training, and supervision to ensure that operating power press brakes safely by maintaining a safe distance from the point of operation.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 G01
- Issued
- Jun 18, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a)Hydro Extrusion USA, LLC at 2500 Alumax Road, Yankton, SD 57078: On or about and at times prior to January 23, 2020, the employer did not ensure employees were protected from electrical hazards associated with not providing sufficient access and working space around electrical equipment. An electrical panel located near the entrance to the maintenance shop was blocked by five gallon pails of materials, various cords and miscellaneous items which impeded access. The condition exposed employees to electrical hazards.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Hydro Extrusion USA, LLC
View Hydro Extrusion USA, LLC's full OSHA safety record →
More inspections in this industry (NAICS 423510)
More inspections in SD
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344580105.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.