Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DYNAMIC CONTRACTING SERVICES, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of DYNAMIC CONTRACTING SERVICES, LLC in SEARS BUILDING NORTH AVE & FON DU LAC AVE, MILWAUKEE, WI 53201 (NAICS 562910). OSHA activity number 344589122.

Watch Dynamic Contracting Services, LLC — free Get an email when a new federal OSHA severe-injury report for Dynamic Contracting Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
SEARS BUILDING NORTH AVE & FON DU LAC AVE
City
MILWAUKEE
State
WI
ZIP
53201
Mailing
50W254 KESLINGER ROAD, MAPLE PARK, IL 60151
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.502 D06 III

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 5, 2020
Abate by
Jun 24, 2020
Penalty
Initial $5,398 · Current $2,150 Reduced
29 CFR 1926.502(d)(6)(iii): Snaphooks shall not be engaged to a Dee-ring to which another snaphook or other connector is attached.    (a) On or about January 27, 2020, a laborer disposing of demolition debris from a third floor wall opening, connected their horizontal life to a double eye wire cable choker anchor. A 3M Protecta retractable lanyard was also connected to the choker anchor.  This exposed the employee to a fall hazard of approximately 20 feet.
Recent events (2)
  • — I (S) $2150
  • — Z (S) $5398

1926.502 D16 III

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 5, 2020
Abate by
Jun 24, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:  (a) On or about January 27, 2020, a laborer was disposing of demolition debris from a third floor wall opening without an adequate fall protection system installed. The employer used a fall arrest system composed of a wire cable anchor, retractable lanyard and 50 foot rope life line that would not limit free fall to no more than six (6) feet or contact the lower level. This exposed the employee to a fall hazard of approximately 20 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 C03

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 5, 2020
Abate by
Jul 9, 2020
Penalty
Initial $3,277 · Current $2,150 Reduced
29 CFR 1926.503(c)(3): When inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill, the employer shall retrain the affected employee.    (a) On or about January 27, 2020, the employer did not ensure employee(s) retained adequate knowledge to erect a proper fall arrest system and/or restraint system to protect the employee from falling or to arrest a fall.  The laborer disposing demolition debris from a third floor wall opening erected a fall protection system composed of a wire cable choker anchor point, attached to a retractable lanyard with an attached 50 foot rope life line.  The erection of this fall protection system would not limit free fall to no more than six (6) feet, contact with the lower level, or prevent the employee from falling over the exposed edge. This exposed the employee to a fall hazard of greater than 20 feet.
Recent events (2)
  • — I (S) $2150
  • — Z (S) $3277

View Dynamic Contracting Services, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344589122.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.