Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. CUSTOMS AND BORDER PROTECTION; PORT OF SEATTLE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. CUSTOMS AND BORDER PROTECTION; PORT OF SEATTLE in 1021 KLICKITAT WAY SUITE D 103, SEATTLE, WA 98134 (NAICS 922190). OSHA activity number 344598107.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Customs and Border Protection; Port of Seattle — free Get an email when a new federal OSHA severe-injury report for U.S. Customs and Border Protection; Port of Seattle is published. One employer, no account, unsubscribe in one click.
Site address
1021 KLICKITAT WAY SUITE D 103
City
SEATTLE
State
WA
ZIP
98134
Mailing
1021 KLICKITAT WAY SUITE D 103, SEATTLE, WA 98134
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922190
Employees
14
Ownership type
D

2 citations on file for this inspection.

1910.37 B06

Repeat 4 instances 14 exposed
Issued
Jun 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  a)  Customs and Border Protection, Port of Seattle, 1021 Klickitat Way, Suite D103, Seattle, WA- The EXIT sign near cubicle 201 did not glow in the dark.   b)  Customs and Border Protection, Port of Seattle, 1021 Klickitat Way, Suite D103, Seattle, WA- The EXIT sign near the LAN room did not glow in the dark.   c)  Customs and Border Protection, Port of Seattle, 1021 Klickitat Way, Suite D103, Seattle, WA- The EXIT sign near cubicle 203 did not glow in the dark.   d)  Customs and Border Protection, Port of Seattle, 1021 Klickitat Way, Suite D103, Seattle, WA- The EXIT sign near cubicle 223 did not glow in the dark.   This exposes employees to delayed egress hazards.   The U.S. Customs and Border Protection was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 1130693, citation number 2, item number 2E and was affirmed as a final order on May 26, 2016, with respect to a workplace located at Tacoma, WA.
Recent events (1)
  • — Z (R) $0

1910.303 B02

Repeat Gravity 1 3 instances 4 exposed
Issued
Jun 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a)  Customs and Border Protection, Port of Seattle, 1021 Klickitat Way, Suite D103, Seattle, WA  Office 219; A Keurig was plugged into a surge protector (relocatable power tap). The UL listing states that relocatable power taps are designed for low amperage computer and audiovisual types of equipment, and not appliances.     (b)  Customs and Border Protection, Port of Seattle, 1021 Klickitat Way, Suite D103, Seattle, WA  Area near cubicle 221;  A Hamilton Beech Coffee pot was plugged into a relocatable power tap/ surge protector. The UL listing states that relocatable power taps are designed for low amperage computer and audiovisual types of equipment, and not appliances.     (c)  Customs and Border Protection, Port of Seattle, 1021 Klickitat Way, Suite D103, Seattle, WA  Cubicle 202;  A surge protector/ relocatable power tap was plugged into another surge protector/ relocatable power tap which powered Dell computer equipment and View Sonic monitors. The UL listing states that relocatable power taps are designed to be plugged into an outlet, and not daisy chained and plugged into other relocatable power taps or extension cords.    This exposes employees to possible electrical fire hazards.    The U.S. Customs and Border Protection was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 1303762, citation number 1, item number 1 and was affirmed as a final order on April 24, 2018, with respect to a workplace located at Sumas, WA.  The U.S. Customs and Border Protection was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 1185225, citation number 1, item number 2 and was affirmed as a final order on July 25, 2017, with respect to a workplace located at Point Roberts, WA.  The U.S. Customs and Border Protection was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 1185252, citation number 2, item number 2 and was affirmed as a final order on April 26, 2018, with respect to a workplace located at Blaine, WA.
Recent events (1)