Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECISION ROOFING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRECISION ROOFING LLC in 808 CLAUSS LN, RIVER VALE, NJ 07675 (NAICS 238170). OSHA activity number 344601018.

Watch Precision Roofing LLC — free Get an email when a new federal OSHA severe-injury report for Precision Roofing LLC is published. One employer, no account, unsubscribe in one click.
Site address
808 CLAUSS LN
City
RIVER VALE
State
NJ
ZIP
07675
Mailing
36 WILSON PL, IRVINGTON, NJ 07111
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
1
Ownership type
A

5 citations on file for this inspection.

1926.451 B05 II

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4453.00 · Current $4453.00
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.  a) Building Exterior/Side:  The end of the platform was not designed and installed so that the cantilevered portion of the platform was able to support employees without tipping, the Alum-A-Pole scaffold had an 3 foot overhang over the support, on or about 1/28/2020.
Recent events (1)
  • — Z (S) $4453

1926.451 F06

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4453.00 · Current $4453.00
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note:  Specify distances as indicated in table in paragraph (f)(6) of this section.   Voltage          Minimum distance           Alternatives ____________________ ________________________ _______________________                                               Less than 300 volts.  3 feet (0.9 m)           300 volts to 50 kv.  10 feet (3.1 m)          More than 50 kv.....  10 feet (3.1 m) plus     2 times the length                       0.4 inches (1.0 cm)      of the line                       for each 1 kv over       insulator, but never                       50 kv.                   less than 10                                                feet (3.1 m). ____________________ ________________________ _______________________  a) Building Exterior/Side: An employee was working from an alum-a-pole pump jack scaffold that was erected and used approximately 3 feet from an energized electrical line providing power to a residential house, on or about 1/28/2020.
Recent events (1)
  • — Z (S) $4453

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4453.00 · Current $4453.00
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.  a) Building Exterior/Rear: An employee was exposed to a 16 foot fall hazard while working from an alum-a-pole pump jack scaffold that was not equipped with a guardrail system or other means of acceptable fall protection in place, on or about 1/28/2020.
Recent events (1)
  • — Z (S) $4453

1926.100 A

Repeat Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5090.00 · Current $5090.00
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:   a) Building Exterior/Side: An employee working without hard hat was exposed to electrical burns and shock while engaged in siding instillation next to an energized electrical line, on or about 1/28/2020.  The Precision Roofing LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.100(a), which was contained in OSHA inspection number 1275250, citation number 1, item number 1 and was affirmed as a final order on 12/26/2017, with respect to a workplace located at 749 Marin Ave Lyndhurst, NJ 07071.
Recent events (1)
  • — Z (R) $5090

1926.1053 B01

Repeat Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $3817.00 · Current $3817.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a) Building Exterior/Side: An employee was using a 20 foot extension ladder that did not extend 3 feet above the landing to access a scaffold, on or about 1/28/2020.   Precision Roofing LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.100(a), which was contained in OSHA inspection number 1275250, citation number 1, item number 4 and was affirmed as a final order on 12/26/2017, with respect to a workplace located at 749 Marin Ave Lyndhurst, NJ 07071.
Recent events (1)
  • — Z (R) $3817

View PRECISION ROOFING LLC's full OSHA safety record →