Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SALVATION ARMY OF MERCER COUNTY

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of SALVATION ARMY OF MERCER COUNTY in 818 MERCER STREET, PRINCETON, WV 24740 (NAICS 452112). OSHA activity number 344601034.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Salvation Army of Mercer County — free Get an email when a new federal OSHA severe-injury report for Salvation Army of Mercer County is published. One employer, no account, unsubscribe in one click.
Site address
818 MERCER STREET
City
PRINCETON
State
WV
ZIP
24740
Mailing
818 MERCER STREET, PRINCETON, WV 24740
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
452112
Employees
5
Ownership type
A

11 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 1 1 instance 1 exposed
Issued
May 11, 2020
Abate by
May 29, 2020
Penalty
Initial $5,783 · Current $2,890 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:    (a) Middle Floor HVAC: On or about November31, 2019 and times prior, an employee was exposed to a fall of approximately 7 feet while changing a HVAC filter without utilizing an appropriate fall protection system.     (b) Elevator shaft: On or about January 1, 2019 and times prior, an employee was exposed to a fall of approximately 8 feet while standing on wooden planks going across the top frame of the elevator cage to change a lightbulb without utilizing an appropriate fall protection system.
Recent events (2)
  • — I (S) $2890
  • — Z (S) $5783

1910.28 B11 I

Serious Gravity 1 1 instance 1 exposed
Issued
May 11, 2020
Abate by
Jun 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(11)(i): Each employee exposed to an unprotected side or edge of a stairway landing that is 4 feet (1.2 m) or more above a lower level was not protected by a guardrail or stair rail system;  (a) Middle Floor:  On or about January 31, 2020 and times prior, employees accessed a stairway landing that was over 4 feet above the floor which did not have an adequate guardrail system in place.  Abatement Note:  Guardrail systems must meet the design criteria listed in 29 CFR 1910.29(b).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.29 F04

Serious Gravity 1 1 instance 2 exposed
Issued
May 11, 2020
Abate by
Jun 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.29(f)(4): An opening in a stair rail system exceeded 19 inches at its least dimension:  (a) Middle Floor: On or about January 31, 2020 and times prior, the stairs accessed by employees, did not have a midrail installed on the stair railing which allowed an opening greater than 19 inches between the stair tread and stair rail.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
May 11, 2020
Abate by
Jun 5, 2020
Penalty
Initial $7,711 · Current $3,855 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a) Elevator Shaft - On or about February 1, 2020 and times prior, the employer did not establish an energy control procedure before servicing and maintenance was performed for the elevator, to include but not limited to cleaning out the bottom of the elevator shaft, and changing a light bulb.
Recent events (2)
  • — I (S) $3855
  • — Z (S) $7711

1910.212 A01

Repeat Gravity 5 1 instance 3 exposed
Issued
May 11, 2020
Abate by
Jun 15, 2020
Penalty
Initial $7,711 · Current $3,855 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Princeton, WV - On or about 8/6/19, employees operating an elevator were not protected from moving parts, exposing employees to crushing hazards and the hazard continued to exist as observed during a follow-up inspection on or about January 31, 2020.    Salvation Army Thrift Store was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 1426152, citation number 1, item number 1, and was affirmed as a final order on 12/17/2019, with respect to a workplace located at 818 Mercer Street, Princeton, WV 24740.
Recent events (2)
  • — I (R) $3855
  • — Z (R) $7711

1910.157 E02

Other-than-serious 1 instance 4 exposed
Issued
May 11, 2020
Abate by
May 21, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  (a) Salvation Army, Multiple Locations - on or about January 31, 2020 and times prior, monthly inspections of the fire extinguishers throughout the facility were not being performed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B08 I

Other-than-serious 1 instance 1 exposed
Issued
May 11, 2020
Abate by
Jun 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(8)(i): Electrical equipment was not firmly secured to the surface on which it was mounted:  (a)  Salvation Army, Middle Floor - on or about January 31, 2020 and times prior, an employee was working in direct proximity underneath several unsecured/hanging light switches and electrical outlets.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B07 I

Other-than-serious 1 instance 4 exposed
Issued
May 11, 2020
Abate by
Jun 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment:  (a) Top Floor - On or about January 31, 2020 and times prior, an employee accessed an electrical cabinet that did not have adequate guarding for the breaker opening to prevent a potential electric shock.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 F02

Other-than-serious 1 instance 4 exposed
Issued
May 11, 2020
Abate by
Jun 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  (a) Top Floor - On or about January 31, 2020 and times prior, an employee accessed an electrical cabinet that did not have the circuit breakers appropriately labeled.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 VII

Other-than-serious 1 instance 4 exposed
Issued
May 11, 2020
Abate by
Jun 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(vii): Switchboards, panel boards, and distribution boards installed for the control of light and power circuits, and motor control centers were not located in dedicated spaces and protected from damage:  (a) Top Floor - On or about January 31, 2020 and times prior, electrical cabinets did not have a door or other adequate guarding covering the electrical panels to prevent them from damage.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1030 G02 I

Other-than-serious 1 instance 4 exposed
Issued
May 11, 2020
Abate by
May 21, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(g)(2)(i): The employer did not ensure that each employee with occupational exposure participated in a training program:  (a) Facility grounds: On or about November 31 ,2019 and times prior, employees were picking up used hypodermic needles outside the facility without having bloodborne pathogens training.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Salvation Army of Mercer County's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344601034.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.