Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: POWER STOP, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of POWER STOP, LLC in 7950 JOLIET RD., MC COOK, IL 60525 (NAICS 336340). OSHA activity number 344605985.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Power Stop, LLC — free Get an email when a new federal OSHA severe-injury report for Power Stop, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
POWER STOP, LLC
Site address
7950 JOLIET RD.
City
MC COOK
State
IL
ZIP
60525
Mailing
6112 W. 73RD ST., BEDFORD PARK, IL 60638
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336340
Employees
90
Ownership type
A

5 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 16, 2020
Abate by
May 12, 2020
Penalty
Initial $13,494 · Current $6,747 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:  a)  On or about February 4, 2020, the employer did not ensure when an employee went on top of the Pangborn GN Rotoblast Barrel Tumbler to unclog accumulated metal grit from the machine, the employee was protected from an approximate six (6) feet, five (5) inch fall hazard by a guardrail system, safety net system, or a personal fall arrest system.
Recent events (2)
  • — I (S) $6747
  • — Z (S) $13494

1910.147 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 16, 2020
Abate by
Jun 3, 2020
Penalty
Initial $13,494 · Current $6,747 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a) On or about February 11, 2020, in the warehouse, the employer did not ensure an energy control program consisting of an energy control procedure, employee training and periodic inspections was established for employees performing service and maintenance on machines including, but not limited to, Pangborn GN Rotoblast Barrel Tumbler and its associated equipment.  Employees are required to unclog accumulated metal grit from the machine and its associated equipment without deenergizing and locking out the equipment.
Recent events (2)
  • — I (S) $6747
  • — Z (S) $13494

1910.178 L04 II B

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 16, 2020
Abate by
Apr 30, 2020
Penalty
Initial $7,711 · Current $3,855 Reduced
29 CFR 1910.178(l)(4)(ii)(B): Refresher training in relevant topics was not provided to the operator when the operator was involved in an accident or near-miss incident:  a)  On or about November 22, 2019, in the warehouse, the employer did not ensure a forklift operator received refresher training after being involved in an accident and before being allowed to re-operate a forklift.  An employee was injured after the forklift operator bumped a pallet that contacted the employee, which subsequently caused the employee to strike their right knee into a table.
Recent events (2)
  • — I (S) $3855
  • — Z (S) $7711

1910.212 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 16, 2020
Abate by
May 12, 2020
Penalty
Initial $13,494 · Current $6,747 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) On or about February 11, 2020, in the piston polisher machine area, the employer failed to provide effective guarding to protect employees working at the piston polisher machines from in-going nip points, thereby exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $6747
  • — Z (S) $13494

1910.178 L06

Other-than-serious 13 instances 13 exposed
Issued
Apr 16, 2020
Abate by
May 12, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The certification did not include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation:  a) On or about February 11, 2020, in the warehouse area, the employer failed to provide certification of forklift training that included the name of the operator(s), the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Power Stop, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344605985.